background image

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

MODELS

FTXG25JV1BW
FTXG35JV1BW
FTXG50JV1BW
CTXG50JV1BW

FTXG25JV1BS
FTXG35JV1BS
FTXG50JV1BS
CTXG50JV1BS

English

Deutsch

Français

Nederlands

Español

Italiano

E

λληνικ

ά

Portugues

Pycc

кий

Т

ürkçe

00_CV_3P255639-2A.indd   1

00_CV_3P255639-2A.indd   1

1/27/2011   11:49:52 AM

1/27/2011   11:49:52 AM

Summary of Contents for Super Multi NX FTXG25JV1BW

Page 1: ...JV1BW FTXG35JV1BW FTXG50JV1BW CTXG50JV1BW FTXG25JV1BS FTXG35JV1BS FTXG50JV1BS CTXG50JV1BS English Deutsch Fran ais Nederlands Espa ol Italiano E Portugues Pycc rk e 00_CV_3P255639 2A indd 1 00_CV_3P25...

Page 2: ...the outdoor unit This function is useful when you need to consideration for your neighborhood Page 19 INTELLIGENT EYE The INTELLIGENT EYE sensor detects the human movement in a room If no one is in th...

Page 3: ...9 Operatio n AUTO DRY COOL HEAT FAN Operation 11 Adjusting the Airflow Direction and Rate 13 COMFORT AIRFLOW Operation 15 INTELLIGENT EYE Operation 16 POWERFUL Operation 18 OUTDOOR UNIT QUIET Operati...

Page 4: ...or warm air refrigerant leakage could be the cause Consult your dealer for assistance The refrigerant within the air conditioner is safe and normally does not leak However in the event of a leakage c...

Page 5: ...te around the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunctions smoke or fire when making contact with electrical parts Do not pl...

Page 6: ...table Mode Temperature setting Airflow rate AUTO 25 C AUTO This switch is useful when the remote controller is missing TIMER lamp When operation by timer has been set the multi monitor lamp periodica...

Page 7: ...ilter Titanium apatite photocatalytic air purifying filter Refrigerant piping and inter unit wiring Earth terminal It is inside of this cover Drain hose Air inlet back and side Air outlet Outdoor temp...

Page 8: ...have an adverse influence on the reception performance of the receiver and the reception distance may be shortened FAN setting button It selects the airflow rate setting Page 14 POWERFUL button POWERF...

Page 9: ...button Page 10 QUIET button OUTDOOR UNIT QUIET operation Page 19 COMFORT button COMFORT AIRFLOW operation Page 15 OFF TIMER button Page 21 TIMER CANCEL button It cancels the timer setting Page 21 22 I...

Page 10: ...ar If the remote controller display begins to fade and the degradation of reception performance occurs within a year however replace both batteries with new size AAA LR03 alkaline The attached batteri...

Page 11: ...ens and closes once to set the reference position To set the clock Press 1 is displayed on the LCD and blink Press 2 to set the current day of the week Press 3 blinks Press 4 to set the clock to the p...

Page 12: ...the room by circulating hot air around all parts of the room After the start of HEAT operation it takes some time before the room gets warmer In HEAT operation frost may occur on the outdoor unit and...

Page 13: ...Other outdoor units 15 20W The outdoor unit consumes 40 to 55W of power at the time of compressor preheating If you are not going to use the air conditioner for a long period for example in spring or...

Page 14: ...rom the LCD To adjust the louvers at desired position Hold the knob and move the louvers You will find a knob on the left side and the right side blades When the unit is installed in the corner of a r...

Page 15: ...it Stop operation Stop operation Stop operation Upper limit COMFORT AIRFLOW Upper limit 5 10 60 20 70 75 75 5 Lower limit Lower limit Note on airflow rate setting At smaller airflow rates the cooling...

Page 16: ...ps will return to the memory position from before COMFORT AIRFLOW operation disappears from the LCD COOL operation HEAT operation NOTE Notes on COMFORT AIRFLOW operation The flaps position will change...

Page 17: ...es to energy saving operation To start INTELLIGENT EYE operation Press is displayed on the LCD The INTELLIGENT EYE lamp lights up Display To cancel INTELLIGENT EYE operation Press again disappears fro...

Page 18: ...ct undesirable objects Do not hit or violently push the INTELLIGENT EYE sensor This can lead to damage and malfunction Example When someone is in the room Normal operation The air conditioner is in no...

Page 19: ...is given to the function of whichever button is pressed last POWERFUL operation can only be set when the unit is running Pressing causes the settings to be canceled and the disappears from the LCD POW...

Page 20: ...NIT QUIET operation will work only when this function is set on all operated indoor units However if using priority room setting refer to note for multi system Page 29 This function is available in CO...

Page 21: ...e Maximum during normal operation Maximum during ECONO operation Normal operation ECONO operation From start up until set temperature is reached Running current and power consumption This diagram is a...

Page 22: ...lamp blinks twice The TIMER lamp periodically lights orange Page 5 Display To cancel OFF TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD NOT...

Page 23: ...yed on the LCD The multi monitor lamp blinks twice The TIMER lamp periodically lights orange Page 5 Display To cancel ON TIMER operation Press and setting time disappear from the LCD and day of the we...

Page 24: ...ge 26 6 00 8 30 17 30 22 00 25 C 27 C Program 1 Program 2 Program 3 Program 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings up to programs 1 4 Page 24 8 00 10 00 19 00 21 00 27 C...

Page 25: ...rvation number Pressing changes the reservation number and the day of the week Press 3 The day of the week and reservation number will be set and blink Press 4 to select the desired mode Pressing chan...

Page 26: ...l be set and the temperature blink Press 8 to select the desired temperature The temperature can be set between 10 C and 32 C COOL or AUTO The unit operates at 18 C even if it is set at 10 to 17 C HEA...

Page 27: ...oor unit and check for a receiving tone and flashing the multi monitor lamp The reservation will be copied to the selected day of the week The whole reservation of the selected day of the week will be...

Page 28: ...is switched to setting mode Go to setting mode step 2 Page 24 Press 3 to exit confirming mode To deactivate WEEKLY TIMER operation Press while is displayed on the LCD The will disappear from the LCD...

Page 29: ...are still other reservations WEEKLY TIMER operation will be activated The reservations for each day of the week This function can be used for deleting reservations for each day of the week It can be u...

Page 30: ...sh With the priority room setting active Refer to priority room setting on the next page NIGHT QUIET mode Available only for COOL operation NIGHT QUIET mode requires initial programming during install...

Page 31: ...s in room B C and D Operation mode in room B C and D Status of room B C and D when the unit in room A is in COOL operation COOL or DRY or FAN Current operation mode maintained HEAT The unit enters sta...

Page 32: ...ion and turn the breaker off Do not touch the aluminium fins of the indoor unit If you touch those parts this may cause an injury Air filter Vacuum dust or wash the filter Once every 2 weeks Refer to...

Page 33: ...uum cleaner It is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned with lukewarm water then dry them up in th...

Page 34: ...ith a new filter Do not throw away the filter frame Reuse the filter frame when replacing the titanium apatite photocatalytic air purifying filter Dispose of the old filter as non flammable waste Set...

Page 35: ...he front panel shaft Front panel shaft 3 Slide Front panel locks Open at least 90 degrees 4 Pull 3 Slide 2 Slide 4 Pull 1 Pull Disconnect the front panel shaft on the other side in the same manner Cle...

Page 36: ...d make sure the HEAT operation is not used at the other room before you use the FAN operation Page 29 We recommend periodical maintenance In certain operating conditions the inside of the air conditio...

Page 37: ...nd This sound is generated when the flow of the refrigerant in the air conditioner is switched over Pinging sound This sound is generated when the size of the air conditioner slightly expands or shrin...

Page 38: ...ean the air filters Is there anything to block the air inlet or the outlet of the indoor and the outdoor units Turn the bleaker off and take all obstacles away Then turn it on again and try operating...

Page 39: ...nual Page 9 The outdoor fan rotates while the air conditioner is not in operation After operation is stopped The outdoor fan continues rotating for another 60 seconds for system protection While the a...

Page 40: ...just wait for a while Lightning If lightning may strike the neighbouring area stop operation and turn the breaker off for system protection Disposal requirements Your product and the batteries supplie...

Page 41: ...OUTDOOR UNIT INDOOR UNIT A1 INDOOR UNIT PCB ABNORMALITY A5 FREEZE UP PROTECTION OR HEATING PEAK CUT CONTROL A6 FAN MOTOR DC MOTOR ABNORMALITY C4 INDOOR HEAT EXCHANGER THERMISTOR ABNORMALITY C7 FRONT...

Page 42: ...GE TO MAIN CIRCUIT OR MOMENTARY VOLTAGE LOSS REVERSING SOLENOID VALVE SWITCHING FAILURE FAN MOTOR FAULT NOTE 1 POWER SUPPLY FAULT OR NOTE 2 NOTE The LED5 is only available in the 5M series GREEN NORMA...

Page 43: ...English 42 MEMO 01_EN_3P255639 2A indd 42 01_EN_3P255639 2A indd 42 2 16 2011 2 44 30 PM 2 16 2011 2 44 30 PM...

Page 44: ...3P255639 2A M10B209 1103 HT Two dimensional bar code is a code for manufacturing Quick Reference 00_CV_3P255639 2A indd 2 00_CV_3P255639 2A indd 2 1 27 2011 11 50 03 AM 1 27 2011 11 50 03 AM...

Reviews: