background image

 

Operation manual

4

FDYP + FBQ + FCQ + FCQH + FDQ

Split system air conditioners

3P468514-7 – 12.2016

How to clean the air filter

Clean the air filter when the display shows "

" (TIME TO CLEAN

AIR FILTER).

Increase the frequency of cleaning if the unit is installed in a room
where the air is extremely contaminated.

(As a yardstick for yourself, consider cleaning the filter once half a
year.)

If the dirt becomes impossible to clean, change the air filter. (Air filter
for exchange is optional.)

For FCQ and FCQH units 

(See figure 6)

1

Open the suction grille (action 1 in the illustration).
Push both levers simultaneously in the direction of the arrow as
indicated in the illustration and carefully lower the grille.
(Identical procedure for closing.)

2

Remove the air filter (actions 2 to 4 in the illustration).
Pull the air filter clip on both the bottom left and the right side of
the filter toward you, and detach the filter.

3

Clean the air filter. (Refer to 

figure 3

)

Use vacuum cleaner or wash the air filter with water.
When the air filter is very dirty, use soft brush and neutral
detergent.

4

Remove water and dry in the shade.

5

Install the air filter back in place (perform actions 2 to 4 in the
illustration in reverse order).

Attach the air filter to the suction grille by hanging it over the
projected portion above the suction grille.
Press the bottom of the air filter against the projections on the
bottom of the grille to snap the air filter into its place.

6

Close the suction grille by performing procedure step 1 in
reverse order.

7

After turning on the power, press the FILTER SIGN RESET
button.

The "TIME TO CLEAN AIR FILTER" display vanishes.

For FBQ and FDQ125C5VEB units 

(See figure 7)

1

Open the suction grille. (Only for bottom suction.)

Slide both knobs simultaneously as shown and then pull them
downward.
If chains are present, unhook the chains.

2

Remove the air filters.

Remove the air filters by pulling its cloth upward (rear suction) or
backward (bottom suction).

3

Clean the air filter. (Refer to 

figure 3

)

Use vacuum cleaner or wash the air filter with water.
When the air filter is very dirty, use soft brush and neutral
detergent.
Remove water and dry in the shade.

4

Fix the air filter.

Align the two hanger brackets and push the two clips in their
place (pull the cloth if necessary, rear, bottom suction).
Confirm that the four hangers are fixed.

5

Shut the air inlet grille. (Only for bottom suction.)

6

After turning on the power, press FILTER SIGN RESET button.

The "TIME TO CLEAN AIR FILTER" display is turned off.

For FDYP and 250B8V3B units 

(See figure 5)

1

Remove the screws from the bottom of the filter frame and
remove the filter frame downwards.

2

Clean the air filter. (Refer to 

figure 3

)

Use compressed air for blowing dust particles of the filter. When
the air filter is very dirty, use soft brush and neutral detergent or
wash with hot (30-40°C) water if needed. Do not rub or wring.

3

Remove water and dry in the shade.

4

Fix the air filter. Put the air filter frame back in its position and fix
firmly with the screws.

How to clean the suction grille

(See figure 6)

 (For FCQ and FCQH units only)

1

Open the suction grille (action 1 in the illustration).

Refer to procedure step 1 in 

"How to clean the air filter" on

page 4

.

2

Detach the suction grille (actions 5 to 6 in the illustration).

First detach the 2 strings from the pins of the decoration panel.
Hold the suction grille open at 45 degrees and lift it upward to
unhook it from the decoration panel.

3

Remove the air filter (actions 2 to 4 in the illustration).

Refer to procedure step 2 in 

"How to clean the air filter" on

page 4

.

4

Clean the suction grille.

Wash with a soft bristle brush and neutral detergent or water,
and dry thoroughly.

5

Install the air filter back in place (perform actions 2 to 4 in the
illustration in reverse order).

6

Reattach the suction grille by performing procedure step 2 in
reverse order (perform actions 5 to 6 in the illustration in reverse
order).

7

Close the suction grille by performing procedure step 1 in
reverse order.

How to clean air outlet and outside panels

Clean with soft cloth.

When it is difficult to remove stains, use water or neutral
detergent.

NOTE

Do not wash the air filter with hot water of more than
50°C. Doing so may result in discoloration and/or
deformation.

Do not expose the unit to fire. Doing so may result in
burning.

NOTE

When the suction grille is very dirty, use a typical
kitchen cleaner and let it sit for about 10 minutes.
Then, wash it with water.

Do not wash the suction grille with hot water of more
than 50°C. Doing so may result in discoloration and/or
deformation.

NOTE

Do not use gasoline, benzene, thinner, polishing
powder, liquid insecticide. It may cause discoloring or
warping.

Do not let the indoor unit get wet. It may cause an
electric shock or a fire.

Do not scrub firmly when washing the blade with water.
The surface sealing may peel off.

Do not use water or air of 50°C or higher for cleaning
air filters and outside panels.

Summary of Contents for Super Multi NX FCQ35C8VEB

Page 1: ...FDQ200B8V3B FDQ250B8V3B FBQ35C8VEB FBQ50C8VEB FBQ60C8VEB FBQ71C8VEB FBQ100C8VEB FBQ125C8VEB FBQ140C8VEB FCQ35C8VEB FCQ50C8VEB FCQ60C8VEB FCQ71C8VEB FCQ100C8VEB FCQ125C8VEB FCQ140C8VEB FCQH71D8VEB FCQH...

Page 2: ...5 50 60 RXS35 50 60 3MKS50 4MKS58 75 90 3MXS52 3MXS52 4MXS68 80 80 80 80 80 80 5 43 10 46 15 46 10 46 15 50 5 46 C DB C WB C DB C WB C DB C WB RZQ200 250 18 35 14 28 80 5 46 C DB C WB C DB C WB C DB C...

Page 3: ...ent is transferred to a new user be sure also to hand over the manual Warning Be aware that prolonged direct exposure to cool or warm air from the air conditioner or to air that is too cool or too war...

Page 4: ...dren should be supervised to ensure that they do not play with the appliance Children should be supervised to ensure that they do not play with the unit or its remote controller Accidental operation b...

Page 5: ...s Refer to Maintenance on page 3 MAINTENANCE Read the operation manual supplied with the remote controller If a function that is not available is selected the message NOT AVAILABLE will appear Operati...

Page 6: ...ttom suction 6 After turning on the power press FILTER SIGN RESET button The TIME TO CLEAN AIR FILTER display is turned off For FDYP and FDQ200 250B8V3B units See gure 5 1 Remove the screws from the b...

Page 7: ...ation is different from the remote controller setting For multi split models the micro computer executes the following control depending on the operation mode of other indoor units Before you start to...

Page 8: ...e air lter is clogged Ask a quali ed service person to clean the air lter The system operates but it does not suf ciently cool or heat If the air inlet or outlet of the indoor or the outdoor unit is b...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...3P468514 7 12 2016 Copyright 2016 Daikin...

Reviews: