2
|
Components
Service manual
113
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
To install the streamer unit
1
Install the streamer unit in the correct location on the indoor unit.
a
b
c
c
a
Streamer unit connector
b
Streamer unit
c
Retainer
2
Route the streamer unit harness inside the switch box and through the
retainers.
3
Connect the streamer unit connector to the indoor unit PCB.
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.
2.16 Swing flap motor
2.16.1 Main swing flap motor
Checking procedures
To perform an electrical check of the swing flap motor
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
99].
1
Disconnect the motor connector from the indoor unit PCB.