![background image](http://html1.mh-extra.com/html/daikin/si011187/si011187_removal-procedure_2460044012.webp)
Removal of Electrical Components
Si011187
10
Removal Procedure
2. Remove the electrical
components.
Compressor capacitor (C1R)
Compressor lead wire
S(W) : yellow
C(U) : blue
R(V) : red
1
Disconnect the 3
connectors of the
compressor capacitor
(C1R).
2
Remove the screw and
remove the compressor
capacitor.
3
Cut the clamp.
4
Disconnect the 5
connectors.
Step
Procedure
Points
(R15494)
Compressor
capacitor (C1R)
K1M(4): red
(R17470)
Compressor (R
terminal) : red
Compressor (S
terminal) : yellow
S(W)
(R6761)
C(U)
R(V)
(R11451)
(R11452)
(R11453)
C2R: white
X2M(N)
: white
K1M(A1)
: black
X1M(2)
: white
K1M(A2)
: black