![background image](http://html.mh-extra.com/html/daikin/ryn60hv1a/ryn60hv1a_removal-procedure_2459994025.webp)
Si011088
Removal of Compressor
Removal Procedure
23
8. Removal of Compressor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Remove the nut and
remove the terminal
cover.
2
Disconnect the
compressor lead wires.
S : Yellow
C : Blue
R : Red
3
Remove the gasket.
(R13481)
Terminal cover
(R13482)
C
R
S
(R13618)
(R13483)
Gasket