Outdoor units for pair application

Daikin outdoor units are neat and sturdy and can be mounted easily 
on a roof or terrace or simply placed against an outside wall.

Outdoor units are fitted with a swing compressor, renowned for its low 
noise and high energy efficiency

Summary of Contents for RYN-E3V1B

Page 1: ...i t S k y A R Y N E 3 V 1 B R 4 1 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall Outdoor units are fitted with a swing compressor renowned for its low noise and high energy efficiency ...

Page 2: ...ndard kW 1 55 1 99 Heating Standard kW 1 60 2 04 For combination indoor units outdoor units EER Nominal 3 23 3 02 COP Nominal 3 63 3 43 Energy Labeling Directive Cooling A B Heating A B Annual energy consumption kWh 775 995 2 2 TECHNICAL SPECIFICATIONS RYN50E3V1B RYN60E3V1B Casing Colour Ivory White Dimensions Unit Height mm 735 735 Width mm 825 825 Depth mm 300 300 Packing Height mm 797 797 Width...

Page 3: ...ity 1 1 Item Installation manual Quantity 1 1 Notes Nominal cooling capacities are based on indoor temperature 270CDB 190CWB outdoor temperature 350CDB equivalent refrigerant piping 7 5m level difference 0m Nominal heating capacities are based on indoor temperature 200CDB outdoor temperature 70CDB 60CWB equivalent refrigerant piping 7 5m level difference 0m Sound levels are measured in an anechoic...

Page 4: ...nits R 410A RYN E3V1B 2 Specifications Wiring connections For Power Supply Quantity 3 3 For connection with indoor Quantity 4 4 Remark Including earth wiring Power Supply Intake Outdoor unit only 2 3 ELECTRICAL SPECIFICATIONS RYN50E3V1B RYN60E3V1B ...

Page 5: ... Outdoor Units R 410A RYN E3V1B 1 3 Split Sky Air Outdoor Units 5 3 Features ...

Page 6: ...b temp C EDB Entering dry bulb temp C TC Total capacity kW SHC Sensible heating capacity kW PI Power input kW NOTES 1 Ratings shown are net capacities which include a deduction for indoor fan motor heat 2 shows nominal rated capacities and power input 3 TC PI and SHC must be calculated by interpolation using the figures in the above tables Figures out of the tables should not be used for calculati...

Page 7: ...bulb temp C EDB Entering dry bulb temp C TC Total capacity kW SHC Sensible heating capacity kW PI Power input kW NOTES 1 Ratings shown are net capacities which include a deduction for indoor fan motor heat 2 shows nominal rated capacities and power input 3 TC PI and SHC must be calculated by interpolation using the figures in the above tables Figures out of the tables should not be used for calcul...

Page 8: ...bulb temp C EDB Entering dry bulb temp C TC Total capacity kW SHC Sensible heating capacity kW PI Power input kW NOTES 1 Ratings shown are net capacities which include a deduction for indoor fan motor heat 2 shows nominal rated capacities and power input 3 TC PI and SHC must be calculated by interpolation using the figures in the above tables Figures out of the tables should not be used for calcul...

Page 9: ... temp C EDB Entering dry bulb temp C TC Total capacity kW SHC Sensible heating capacity kW PI Power input kW NOTES 1 Ratings shown are net capacities which include a deduction for indoor fan motor heat 2 shows nominal rated capacities and power input 3 TC PI and SHC must be calculated by interpolation using the figures in the above tables Figures out of the tables should not be used for calculatio...

Page 10: ...um space for air passage Wall height on air outlet side less than 1200 Drain outlet I D J 15 9 hose for connection 4 x holes for anchor bolts M8 or M10 Name plate Terminal strip with earth terminal Wiring inlet Gas stop valve J 12 7 CuT Liquid stop valve J 6 4 CuT Service port Outdoor air temperature thermistor Brand name label In case of removing stop valve cover ...

Page 11: ... Outdoor Units R 410A RYN E3V1B 1 5 Split Sky Air Outdoor Units 11 5 Dimensional drawing centre of gravity 5 2 Centre of gravity 4D051638C RYN50 60E The position of foundation bolt ...

Page 12: ...er fan Capillary tube 1 Liquid stop valve Field piping Field piping Gas stop valve with service port Compressor Capillary tube 3 Refrigerant flow Cooling Heating Discharge pipe thermistor Heat exchanger thermistor Capillary tube 2 Capillary tube 4 Muffler with filter Motor operated valve Receiver Filter Outdoor unit Muffler Four way valve on heating Muffler ...

Page 13: ...2 Operation noise differs with operation and ambient conditions 3 The operation noise measuring method is in accordance with JISC9612 Legend 50Hz 220 240V 3D051716A Octave band sound pressure level Octave band center frequency Hz RYN60E Cooling approximate threshold hearing for continuous noise NOTES 1 Measure in anechoic room 2 Operation noise differs with operation and ambient conditions 3 The o...

Page 14: ...28318K RYN50 60E Outdoor temp CDB Pull down period Indoor temp CWB Notes The graphs are based on the following conditions Equivalent piping length 7 5 m Level difference 0 m Air flow rate high Cooling Heating Indoor temp CDB Outdoor temp CWB Continuous operation Continuous operation 15 CDB ...

Page 15: ... Outdoor Units R 410A RYN E3V1B 1 8 Split Sky Air Outdoor Units 15 8 Operation range ...