1. Safety cautions .......................................................................... 1

2. Important information regarding the refrigerant used ................ 2

3. What to do before operation ...................................................... 2

4. Remote controller....................................................................... 3

5. Changeover switch: Name and function of each switch ............. 3

6. Operation range ......................................................................... 3

7. Operation procedure .................................................................. 3

 

7.1. Cooling, heating, fan only, and automatic operation .................... 3
7.2. Program dry operation ................................................................. 4
7.3. Adjusting the air flow direction ..................................................... 4
7.4. Setting the master remote controller ............................................ 5
7.5. Precautions for group control system or two remote controller 

control system .............................................................................. 5

 

8. Energy saving and optimum operation ...................................... 5

9. Maintenance .............................................................................. 6

 

9.1. Maintenance after a long stop period........................................... 6
9.2. Maintenance before a long stop period........................................ 6

 

10. Following symptoms are not air conditioner troubles ................. 6

11. Troubleshooting.......................................................................... 7

12. After-sales service and warranty................................................ 8

 

12.1. After-sales service ....................................................................... 8
12.2. Shortening of "maintenance cycle" and "replacement cycle" 

needs to be considered in following situations ............................. 8

 

1.

S

 

AFETY

 

 

 

CAUTIONS

 

Read the following cautions carefully and use your equipment
properly.

Keep these warning sheets handy so that you can refer to them
if needed.

 

Also, if this equipment is transferred to a new user, make sure to
hand over this user's manual to the new user.

 

Warnings

 

 

It is not good for your health to expose your body to the air flow
for a long time.

 

 

In order to avoid electric shock, fire or injury, or if you detect any
abnormality such as smell of fire, turn off the power supply and
call your dealer for instructions.

 

 

Ask your dealer for installation of the air conditioner.
Incomplete installation performed by yourself may result in a
water leakage, electric shock, and fire.

 

 

Do not place objects in direct proximity of the outdoor unit and
do not let leaves and other debris accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit.
Once in the unit, such animals can cause malfunctions, smoke
or fire when making contact with electrical parts.

 

 

Ask your dealer for improvement, repair, and maintenance.
Incomplete improvement, repair, and maintenance may result in
a water leakage, electric shock and fire.

 

 

Do not insert fingers, rods or other objects into the air inlet or
outlet. When the fan is rotating at high speed, it will cause injury.

 

 

Never let the indoor unit or the remote controller get wet.
It may cause an electric shock or a fire.

 

 

Never use a flammable spray such as hair spray, lacquer or paint
near the unit.
It may cause a fire.

 

 

Never touch the air outlet or the horizontal blades while the
swing flap is in operation.
Fingers may become caught or the unit may break down.

 

 

Never replace a fuse with that of wrong ampere ratings or other
wires when a fuse blows out.
Use of wire or copper wire may cause the unit to break down or
cause a fire.

 

 

Never put any objects into the air inlet or outlet.
Objects touching the fan at high operating speed can be
dangerous.

 

 

Never press the button of the remote controller with a hard,
pointed object.
The remote controller may be damaged.

 

 

Never pull or twist the electric wire of the remote controller.
It may cause the unit to malfunction.

 

 

Never inspect or service the unit by yourself.
Ask a qualified service person to perform this work.

 

 

To prevent refrigerant leak, contact your dealer.
When the system is installed and runs in a small room, it is
required to keep the concentration of the refrigerant, if by any
chance coming out, below the limit. Otherwise, oxygen in the
room may be affected, resulting in a serious accident.

 

 

The refrigerant in the air conditioner is safe and normally does
not leak. If the refrigerant leaks in the room, contact with a fire of
a burner, a heater or a cooker may result in a harmful gas.
Turn off any combustible heating devices, ventilate the room and
contact the dealer where you purchased the unit.
Do not use the air conditioner until a service person confirms
that the portion where the refrigerant leaks is repaired.

 

 

Improper installation or attachment of equipment or accessories
could result in electric shock, short-circuit, leaks, fire or other
damage to the equipment. Be sure to use only accessories
made by Daikin which are specifically designed for use with the
equipment and have them installed by a professional.

 

 

Ask your dealer to move and reinstall the air conditioner.
Incomplete installation may result in a water leakage, electric
shock, and fire.

 

RX(Y)Q5~12P7W1B

RXYQ8~12P7W1B1

RX(Y)Q14~18P7W1BA

REMQ8~16P7Y1B

RXYQ8~12P7W1B1

RXYSQ4~6P7V3B

RXYQ14~18P7W1B1A

RXYSQ4~6P7Y1B

 

VRVIII and VRVIII-S system air conditioner

 

Operation manual

 

Thank you for purchasing this Daikin air conditioner.
Carefully read this operation manual before using the air
conditioner. It will tell you how to use the unit properly and
help you if any trouble occurs. After reading the manual,
file it away for future reference.

 

WARNING

 

Improper handling can lead to such serious consequences
as death, severe injury or damage to the equipment.

 

NOTE

 

These instructions will ensure proper use of the
equipment.

Be sure to follow these important safety cautions.

Summary of Contents for RXYQ16P7W1BA4 RXYQ18P7W1BA

Page 1: ...Q8P7W1B RXYQ10P7W1B RXYQ12P7W1B RXYQ14P7W1BA RXYQ16P7W1BA RXYQ18P7W1BA RXYQ8P7W1B1 RXYQ10P7W1B1 RXYQ12P7W1B1 RXYQ14P7W1B1A RXYQ16P7W1B1A RXYQ18P7W1B1A REMQ8P7Y1B REMQ10P7Y1B REMQ12P7Y1B REMQ14P7Y1B RE...

Page 2: ...4 1 2 3 1 1 4 2 2 3 1 1 4 3 9 2 3 1 3 1 2 1 1 5 3 5 2 4 6 UNIT NO 1 2 3 4 2 1 2 7 C D A B 8 RXYSQ RXYQ REYQ REMQ REMQ RXYSQ RXYQ REYQ REMQ REMQ 1 5 5 3 4 6 1 5 5 6 4 4 1 4 3 2 7 6 5 1 5 4 1 2 3 4 1 4...

Page 3: ...spray such as hair spray lacquer or paint near the unit It may cause a fire Never touch the air outlet or the horizontal blades while the swing flap is in operation Fingers may become caught or the un...

Page 4: ...result in injury Do not place a flower vase or anything containing water on the unit Water may enter the unit causing an electric shock or fire Do not place the controller exposed to direct sunlight T...

Page 5: ...djust itself depending on the room temperature or the fan may stop immediately This is not a malfunction For systems without cool heat changeover remote control switch See figure 3 1 Press the operati...

Page 6: ...ystem starts operation 4 Press the air flow direction adjust button Only for Double flow Multi flow Corner Ceiling suspended and Wall mounted Refer to 7 3 Adjusting the air flow direction on page 4 fo...

Page 7: ...remote controller controls up to 16 indoor units All indoor units are equally set Two remote controller control system Two remote controllers control one indoor unit in case of group control system on...

Page 8: ...is turned on The micro computer is getting ready to operate Wait 10 minutes Symptom 4 The fan strength does not correspond to the setting The fan strength does no change even if the fan strength adju...

Page 9: ...unit Measure Stop the operation The operation switch does not work well Measure Turn off the power If the display the unit number and the operation lamp flash and the malfunction code appears See fig...

Page 10: ...nditioning Recommended replacement cycle of wear parts Table 2 Replacement Cycle list Contact your dealer for details Moving and discarding the unit Contact your dealer for removing and reinstalling t...