background image

Read these 

Safety Considerations for Operations

 carefully 

before installing air conditioner or heat pump. Make sure that 
the unit operates properly during the startup operation. 
Instruct the customer on how to operate and maintain the unit.
Inform customers that they should store this Operation 
Manual with the Installation Manual for future reference.
Meanings of 

DANGER, WARNING, CAUTION,

 and 

NOTE

Symbols:

DANGER

 ............Indicates an imminently hazardous 

situation which, if not avoided, will result 
in death or serious injury.

WARNING

 ..........Indicates a potentially hazardous 

situation which, if not avoided, could 
result in death or serious injury.

CAUTION

 ...........Indicates a potentially hazardous 

situation which, if not avoided, may 
result in minor or moderate injury. It 
may also be used to alert against 
unsafe practices.

NOTE

 .................Indicates situations that may result in 

equipment or property-damage 
accidents only.

DANGER

materials are present due to risk of explosion resulting 

in serious injury or death.

Any abnormalities in the operation of the air 

result in severe injury or death. Turn off the power and 

contact your dealer immediately.

Refrigerant gas may produce toxic gas if it comes into 

cooking device. Exposure to this gas will result in 

severe injury or death.

For refrigerant leakage, consult your dealer.

Refrigerant gas is heavier than air and replaces 

oxygen. A massive leak will result in oxygen depletion, 

especially in basements, and an asphyxiation hazard 

will result leading to serious injury or death.

If equipment utilizing a burner is used in the same 

room as the air conditioner or heat pump, there is the 

asphyxiation hazard resulting in serious injury or 

avoid this hazard.

Safely dispose all packing and transportation 

materials in accordance with federal/state/local laws 

or ordinances. Packing materials such as nails and 

other metal or wood parts, including plastic packing 

materials used for transportation may cause injuries 

or death by suffocation.

WARNING

Contact your dealer for repair and maintenance. 

Improper repair and maintenance could result in water 

with the equipment and have them installed by a 

professional.

Contact your dealer to move and reinstall the air 

conditioner or heat pump. Incomplete installation 

Never let the indoor unit or the remote controller get 

lacquer, or paint near the unit. Flammable spray could 

When a fuse blows out, never replace it with one of 

incorrect ampere ratings or different wires. Always 

replace any blown fuse with a fuse of the same 

Never remove the fan guard of the unit. A fan rotating 

at high speed without the fan guard is very dangerous 

and could result in injury.

Never inspect or service the unit by yourself. Contact 

Turn off all electrical power before doing any 

maintenance to avoid the risk of serious electric 

shock; never sprinkle or spill water or liquids on the 

unit.

electric shock.

Do not allow children to play on or around the unit to 

prevent injury.

working around them.

air outlet. The fan is rotating at high speed and could 

result in injury.

Check the unit foundation for damage on a continuous 

basis, especially if it has been in use for a long time. If 

left in a damaged condition the unit may fall and could 

result in injury.

if a spill occurs.

Do not touch the air outlet or horizontal blades while 

getting caught and injured.

Never touch the internal parts of the controller. Do not 

remove the front panel because some parts inside are 

dangerous to touch. To check and adjust internal 

parts, contact your dealer.

Be sure to establish a ground.

Do not ground the unit to a utility pipe, arrester, or 

telephone ground. Incomplete grounding may cause 

lightning or other sources may cause damage to the 

air conditioner.

Safety Considerations

i

English

Summary of Contents for RXSQ48TAVJU

Page 1: ...JU Residential VRV System air conditioner Residential VRV System air conditioner Conditionneur d air Residential VRV System Sistema de acondicionador de aire Residential VRV RXSQ36TAVJU RXSQ48TAVJU RX...

Page 2: ...tate local laws or ordinances Packing materials such as nails and other metal or wood parts including plastic packing materials used for transportation may cause injuries or death by suffocation WARNI...

Page 3: ...r to direct sunlight The LCD display can become discolored and may result in fail to display the data Do not wipe the controller operation panel with benzene thinner chemical dust cloth etc The result...

Page 4: ...g work unless you are licensed to do so Consult with your local dealer for electrical work and grounding work Use a dedicated circuit for the air conditioner Pay Attention to Operating Sound Be sure t...

Page 5: ...ation Range 3 Operation Procedure 4 Name and Function of Each Switch and Display 4 Maintenance 6 Reference Information 7 Optimum Operation 8 Seasonal Maintenance 8 Following Issues Do Not Mean System...

Page 6: ...Pa Low side psig MPa 39 37 12 5 8 990 940 320 RXSQ24TAVJU SINGLE 60 208 230 23 000 25 000 172 78 R410A 6 4 2 9 478 3 3 362 2 5 RXSQ36TAVJU SINGLE 60 208 230 34 200 37 000 172 78 R410A 6 4 2 9 478 3 3...

Page 7: ...he air conditioner is operated continuously while the indoor temperature is 70 FDB 21 CDB or below and the humidity is 80 or over the interiors of the indoor units may cause icing and water leakage ma...

Page 8: ...manual that came with the remote controller Operation Procedure Operation procedure varies according to the combination of outdoor unit and remote controller Read the chapter What to do before Operat...

Page 9: ...Auto are all only available for selection on the COOL HEAT changeover master indoor unit The following table indicates the available operating modes of the other indoor units on the system based upon...

Page 10: ...3 Setting Main Menu Reset Filter Indicator Air Flow Direction Ventilation Schedule Off Timer Celsius Fahrenheit 1 2 Cool Set to Cool 74F Press buttons to select Reset Filter Indicator on the main men...

Page 11: ...r local dealer of the Error code and model name or code Precautions for Group Control System or Two Remote Controller Control System This system provides two other control systems beside individual co...

Page 12: ...for the room temperature to reach the set temperature We recommend starting the operation in advance using schedule operation Seasonal Maintenance Caution Touching them may result in injury Do not wa...

Page 13: ...es away Cool heat cannot be changed over When the display shows MASTER CONTROLLED It shows that this is a slave remote controller Refer to Setting the Cool Heat Change over Master When the Cool Heat s...

Page 14: ...e dripping water is heard while the indoor unit is stopped When the other indoor unit is in operation this noise is heard In order to prevent oil and refrigerant from remaining in the system a small a...

Page 15: ...vestigate the system according to the following procedures Let them know the symptoms system name and model name 1 If the system does not operate at all Check if there is no power failure Wait until p...

Page 16: ...hock or re Contact your local dealer When asking your local dealer to repair inform related staff of the details as follows Model name and product No of air conditioner Shipping date and installation...

Page 17: ...equency wave distortion etc is high Cannot be used if it is outside the allowable range 3 When installed and used in locations where bumps and vibrations are frequent 4 When used in bad locations wher...

Page 18: ...rocarbon Contact your local dealer for discarding this unit since it is required by law to collect transport and discard the refrigerant in accordance with chloro uorocarbon collection and destruction...

Page 19: ......

Page 20: ...5151 San Felipe Suite 500 Houston TX 77056 1706 HTS 3P435466 2D...

Reviews: