background image

Removal of Four Way Valve

Si00-974

18

Removal Procedure

„

Before working, make 
sure that the refrigerant 
gas is empty in the circuit.

„

Be sure to apply nitrogen 
replacement when 
heating up the brazed 
part.

Warning

Be careful not to get yourself 
burnt with the pipes and other 
parts that are heated by the 
gas brazing machine.

Warning

If the refrigerant gas leaks 
during work, ventilate the 
room. (If the refrigerant gas is 
exposed to flames, toxic gas 
may be generated.)

Caution

From the viewpoint of global 
environment protection, do 
not discharge the refrigerant 
gas in the atmosphere. Make 
sure to collect all the 
refrigerant gas.

Cautions for restoration

1. Restore the piping by non-

oxidation brazing. 

2. It is required to prevent the 

carbonization of the oil inside 
the four way valve and the 
deterioration of the gaskets 
affected by heat. (Keep 
below 120°C.) For the sake 
of this, wrap the four way 
valve with wet cloth and 
provide water so that the 
cloth does not dry.

In case of difficulty with gas 
brazing machine 

1. Disconnect the brazed part 

where is easy to disconnect 
and restore.

2. Cut pipes on the main unit 

with a tube cutter in order to 
make it easy to disconnect.

2. Remove the four way 

valve.

1

Heat up the brazed part 
(a) and withdraw the 
piping with pliers.

2

Heat up the 3 brazed 
parts of the four way 
valve. Disconnect the 
point (b) first.

3

Disconnect the points 
(c) and (d).

Note:

„

Do not use a metal saw 
for cutting pipes by all 
means because the 
sawdust comes into the 
circuit.

„

When withdrawing the 
pipes, be careful not to 
pinch them firmly with 
pliers. The pipes may get 
deformed.

„

Provide a protective sheet 
or a steel plate so that the 
brazing flame cannot 
influence peripheries.

Step

Procedure

Points

(R7418)

(a)

(R7419)

(R7420)

(d)

(c)

(b)

Summary of Contents for RXS25HV2C

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L 2 5 3 2 3 5 kW Class Outdoor Unit Inverter Pair Type Si00 974...

Page 2: ...Service Manual Removal Procedure Outdoor Unit zHeat Pump RXS25HV2C RXP25HV2C RXP32HV2C RXP35HV2C...

Page 3: ...al of Outer Panels 2 2 Removal of Outdoor Fan Fan Motor 4 3 Removal of Electrical Box PCBs 6 4 Removal of Sound Blankets 14 5 Removal of Four Way Valve 16 6 Removal of Compressor 19 Note The illustrat...

Page 4: ...work Step Procedure Points 1 Appearance features Take care not to cut your finger by the fins of the outdoor heat exchanger 2 Remove the panels The stop valve cover is united with the shield plate Whe...

Page 5: ...move the 5 screws of the front panel 4 Lift up the left side and unfasten the hooks 5 Unfasten the right side hooks and remove the front panel 6 7 Remove the 4 screws of the discharge grille Unfasten...

Page 6: ...according to the Removal of Outer Panels Nut size M6 1 2 Remove the nut of the outdoor fan Remove the outdoor fan When reassembling align the mark of the outdoor fan with the D cut section of the moto...

Page 7: ...motor lead wire from the hooks When reassembling put the fan motor lead wire through the back of the fan motor so as not to be entangled with the outdoor fan 5 Remove the 3 screws and remove the fan...

Page 8: ...g work Step Procedure Points 1 Remove the right side panel Preparation Remove the panels according to the Removal of Outer Panels 1 Unhook the outdoor temperature thermistor 2 Release the outdoor temp...

Page 9: ...e 7 5 Remove the screw on the rear side of the right side panel 6 Remove the 4 screws on the right side panel 7 Unfasten the hook on the rear side When reassembling make sure to fit the hook Step Proc...

Page 10: ...electrical box 9 Unfasten the hook and remove the right side panel 2 Remove the electrical box 1 Disconnect the connector for the four way valve coil S80 2 Disconnect the connector for the overload pr...

Page 11: ...e for the electronic expansion valve coil 5 Disconnect the relay connector for the compressor Pay attention so as not to lose the fixture for the thermistor When reassembling do not insert the thermis...

Page 12: ...lose the clip for the thermistor 8 Cut the clamp 9 Unfasten the hook from the partition plate with a flat screwdriver The electrical box can be removed by lifting itself without a screwdriver 10 Lift...

Page 13: ...1 3 Remove the main PCB 1 Remove the screw on the terminal board 2 Cut the clamp 3 Remove the 2 screws of the earth wire 4 Disconnect the 2 terminals of the reactor Step Procedure Points R15865 Termin...

Page 14: ...5 Remove the 3 screws to remove the reactor 6 Disconnect the connector for the thermistors S90 7 Remove the 6 screws 8 Disconnect the 3 connectors for the filter PCB S10 HL3 HN3 Step Procedure Points...

Page 15: ...he 2 hooks 10 Lift and remove the main PCB 11 Feature of the main PCB S10 HL3 HN3 filter PCB S20 electronic expansion valve coil S40 overload protector S70 fan motor S80 four way valve coil S90 thermi...

Page 16: ...more after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the partition plate 1 Remove the 2 screws 2 The partition plate has a hook on the lower side Lift an...

Page 17: ...the sound blanket are torn easily remove the blanket carefully 1 Lift and remove the sound blanket top 2 Pull the sound blankets outer inner 2 out 3 Pull the sound blanket inner 1 out Step Procedure...

Page 18: ...power supplies before disassembling work Step Procedure Points 1 Remove the peripheries There are 2 hooks at the inner side of the terminal cover 1 Remove the screw and remove the four way valve coil...

Page 19: ...Si00 974 Removal of Four Way Valve Removal Procedure 17 4 Remove the electronic expansion valve coil 5 Remove the putty Step Procedure Points R7415 Electronic expansion valve coil Putty R7416...

Page 20: ...e four way valve and the deterioration of the gaskets affected by heat Keep below 120 C For the sake of this wrap the four way valve with wet cloth and provide water so that the cloth does not dry In...

Page 21: ...he sake of this wrap the four way valve with wet cloth and provide water so that the cloth does not dry In case of difficulty with gas brazing machine 1 Disconnect the brazed part where is easy to dis...

Page 22: ...Revision History Month Year Version Revised contents 02 2013 Si00 974 First edition...

Page 23: ...ies supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acces...