background image

 

OPERATION MANUAL

 

RXQ5M7W1B
RXQ8M8W1B
RXQ10M8W1B

RXYQ5M7W1B
RXYQ8M8W1B
RXYQ10M8W1B
RXYQ12M8W1B
RXYQ14M8W1B
RXYQ16M8W1B

RXYQ18M7W1B
RXYQ20M7W1B
RXYQ22M7W1B
RXYQ24M7W1B
RXYQ26M7W1B
RXYQ28M7W1B
RXYQ30M7W1B
RXYQ32M7W1B
RXYQ34M7W1B
RXYQ36M7W1B
RXYQ38M7W1B
RXYQ40M7W1B
RXYQ42M7W1B
RXYQ44M7W1B
RXYQ46M7W1B
RXYQ48M7W1B

RXQ5M9W1B
RXQ8M9W1B
RXQ10M9W1B

RXYQ5M9W1B
RXYQ8M9W1B
RXYQ10M9W1B
RXYQ12M9W1B
RXYQ14M9W1B
RXYQ16M9W1B

RXYQ18M9W1B
RXYQ20M9W1B
RXYQ22M9W1B
RXYQ24M9W1B
RXYQ26M9W1B
RXYQ28M9W1B
RXYQ30M9W1B
RXYQ32M9W1B
RXYQ34M9W1B
RXYQ36M9W1B
RXYQ38M9W1B
RXYQ40M9W1B
RXYQ42M9W1B
RXYQ44M9W1B
RXYQ46M9W1B
RXYQ48M9W1B

RXYSQ4M7V3B
RXYSQ5M7V3B
RXYSQ6M7V3B

REYQ8M7W1B
REYQ10M7W1B
REYQ12M7W1B
REYQ14M7W1B
REYQ16M7W1B

REYQ18M7W1B
REYQ20M7W1B
REYQ22M7W1B
REYQ24M7W1B
REYQ26M7W1B
REYQ28M7W1B
REYQ30M7W1B
REYQ32M7W1B
REYQ34M7W1B
REYQ36M7W1B
REYQ38M7W1B
REYQ40M7W1B
REYQ42M7W1B
REYQ44M7W1B
REYQ46M7W1B
REYQ48M7W1B

 

 and 

System air conditioner

Summary of Contents for RXQ5M7W1B

Page 1: ...9W1B RXYQ10M9W1B RXYQ12M9W1B RXYQ14M9W1B RXYQ16M9W1B RXYQ18M9W1B RXYQ20M9W1B RXYQ22M9W1B RXYQ24M9W1B RXYQ26M9W1B RXYQ28M9W1B RXYQ30M9W1B RXYQ32M9W1B RXYQ34M9W1B RXYQ36M9W1B RXYQ38M9W1B RXYQ40M9W1B RXY...

Page 2: ...2 3 1 1 4 3 2 3 1 3 1 2 1 1 5 3 5 2 4 6 UNIT NO 1 2 3 4 2 1 2 7 Ceiling Suspended Wall Mounted Double flow Multi flow Corner 8 RXYSQ RXYQ 1 1 4 4 3 2 6 7 5 5 REYQ 1 RXYSQ RXYQ 1 5 5 4 3 2 4 7 1 5 5 4...

Page 3: ...y for future reference WARNING Improper handling can lead to such serious consequences as death severe injury or damage to the equipment NOTE These instructions will ensure proper use of the equipment...

Page 4: ...door unit It may cause incomplete combustion or deformation of the unit due to the heat Do not allow a child to mount on the outdoor unit or avoid placing any object on it Falling or tumbling may resu...

Page 5: ...rt automatically after the power turns back on again 6 1 Cooling heating fan only and automatic operation See figure 3 and figure 4 1 Changeover cannot be made with a remote controller whose display s...

Page 6: ...dry operation Press the on off button The operation lamp lights up and the system starts operation Press the air flow direction adjust button Only for Double flow Multi flow Corner Ceiling suspended a...

Page 7: ...ller control system Two remote controllers control one indoor unit in case of group control system one group of indoor units The unit is individually operated 7 ENERGY SAVING AND OPTIMUM OPERATION Obs...

Page 8: ...he power is turned on The micro computer is getting ready to operate Wait 10 minutes Symptom 4 The fan strength does not correspond to the setting The fan strength does no change even if the fan stren...

Page 9: ...e power If the display the unit number and the operation lamp flash and the malfunction code appears See figure 6 Measure Notify your dealer and report the malfunction code If the system does not prop...

Page 10: ...ong sites with 24 hour air conditioning Recommended replacement cycle of wear parts Table 2 Replacement Cycle list Contact your dealer for details Moving and discarding the unit Contact your dealer fo...

Page 11: ...NOTES NOTES...

Page 12: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN16234 1C...

Reviews: