Program dry operation

The function of this program is to decrease the humidity in your
room with minimal temperature decrease (minimal room
cooling).

The micro computer automatically determines temperature and
fan speed (cannot be set by the remote controller).

The system does not go into operation if the room temperature
is low (<20°C).

For systems without cool/heat changeover remote control 
switch

1

Press the operation mode selector button several times and
select 

 (program dry operation).

2

Press the on/off button.

The operation lamp lights up and the system starts operation.

3

Press the air flow direction adjust button. (Only for Double-flow,
Multi-flow, Corner, Ceiling-suspended and Wall-mounted.) Refer
to 

"6.3. Adjusting the air flow direction" on page 4

 for details.

Stopping the system

4

Press the on/off button once again.

The operation lamp goes off and the system stops operation.

For systems with cool/heat changeover remote control switch 

(See figure 5)

1

Select cooling operation mode with the cool/heat changeover
remote control switch.

2

Press the operation mode selector button several times and
select 

 (program dry operation).

3

Press the on/off button.

The operation lamp lights up and the system starts operation.

4

Press the air flow direction adjust button. (Only for Double-flow,
Multi-flow, Corner, Ceiling-suspended and Wall-mounted.) Refer
to 

"6.3. Adjusting the air flow direction" on page 4

 for details.

Stopping the system

5

Press the on/off button once again.

The operation lamp goes off and the system stops operation.

6.3.

Adjusting the air flow direction

Refer to the operation manual of the remote controller.

Movement of the air flow flap 

(See figure 7)

For the following conditions, a micro computer controls the air flow
direction which may be different from the display.

The air flow direction can be adjusted in one of the following ways.

The air flow flap itself adjusts its position.

The air flow direction can be fixed by the user.

Automatic "

" and desired position "

".

6.4.

Setting the master remote controller

When the system is installed as shown in 

figure 8

, it is necessary to

designate one of the remote controllers as the master remote
controller.

Only the master remote controller can select heating or cooling
operation.

The displays of slave remote controllers show 

 (change-

over under centralized control) and they automatically follow the
operation mode directed by the master remote controller.

However, it is possible to changeover to program dry with slave
remote controllers if the system is in cooling operation set by the
master remote controller.

How to designate the master remote controller

1

Press the operation mode selector button of the current master
remote controller for 4 seconds.

The display showing 

 (change-over under centralized

control) of all slave remote controllers connected to the same
outdoor unit or BS unit flash.

2

Press the operation mode selector button of the controller that
you wish to designate as the master remote controller. Then
designation is completed. This remote controller is designated
as the master remote controller and the display showing 
(change-over under centralized control) vanishes.

The displays of other remote controllers show 

 (change-

over under centralized control).

NOTE

Do not turn off power immediately after the unit stops,
but wait for at least 5 minutes.

NOTE

Do not turn off power immediately after the unit stops,
but wait for at least 5 minutes.

A

Double-flow + Multi-flow units

B

Corner units

C

Ceiling-suspended units

D

Wall-mounted units

COOLING

HEATING

• When the room temperature is lower than 

the set temperature.

• When starting operation.
• When the room temperature is higher than 

the set temperature.

• At defrost operation.

• When operating continuously at horizontal air flow direction.
• When continuous operation with downward air flow is performed at the time of cooling with a 

ceiling-suspended or a wall-mounted unit, the microcomputer may control the flow direction, 
and then the remote control indication also will change.

NOTE

The movable limit of the flap is changeable.
Contact your dealer for details. (Only for Double-
flow, Multi-flow, Corner, Ceiling-suspended and
Wall-mounted.)

Avoid operating in the horizontal direction
"

". It may cause dew or dust to settle on the

ceiling.

Summary of Contents for RXQ14P7W1B

Page 1: ...1B RXQ14P7W1B RXQ16P7W1B RXQ18P7W1B RXYQ5P7W1B RXYQ8P7W1B RXYQ10P7W1B RXYQ12P7W1B RXYQ14P7W1B RXYQ16P7W1B RXYQ18P7W1B RXYQ8P7W1B1 RXYQ10P7W1B1 RXYQ12P7W1B1 RXYQ14P7W1B1 RXYQ16P7W1B1 RXYQ18P7W1B1 RXYSQ4P7V3B RXYSQ5P7V3B RXYSQ6P7V3B and System air conditioner ...

Page 2: ...4 1 5 5 3 2 4 RXQ 4 1 2 3 1 1 4 2 2 3 1 1 4 3 2 3 1 3 1 2 1 1 5 3 5 2 4 6 UNIT NO 1 2 3 4 2 1 2 7 C D A B 8 RXYSQ RXYQ RXYSQ RXYQ 1 5 5 3 2 4 6 1 5 5 6 4 4 1 1 2 3 4 1 4 2 4 3 5 6 7 8 ...

Page 3: ... such as hair spray lacquer or paint near the unit It may cause a fire Never touch the air outlet or the horizontal blades while the swing flap is in operation Fingers may become caught or the unit may break down Never replace a fuse with that of wrong ampere ratings or other wires when a fuse blows out Use of wire or copper wire may cause the unit to break down or cause a fire Never put any objec...

Page 4: ...the unit carelessly it may result in injury Do not place a flower vase or anything containing water on the unit Water may enter the unit causing an electric shock or fire Do not place the controller exposed to direct sunlight The LCD display may get discolored failing to display the data Do not wipe the controller operation panel with benzine thinner chemical dustcloth etc The panel may get discol...

Page 5: ...set temperature for general heating operation than for cooling operation The following operation is performed in order to prevent the heating capacity from dropping or cold air from blowing Defrost operation heat pump and heat recovery types only In heating operation freezing of the outdoor unit coil increases Heating capability decreases and the system goes into defrost operation The indoor unit ...

Page 6: ...sired position 6 4 Setting the master remote controller When the system is installed as shown in figure 8 it is necessary to designate one of the remote controllers as the master remote controller Only the master remote controller can select heating or cooling operation The displays of slave remote controllers show change over under centralized control and they automatically follow the operation m...

Page 7: ... and outdoor units Clean air filters and casings of indoor units Refer to the operation manual supplied with the indoor units for details on how to proceed and make sure to install cleaned air filters back in the same position Turn on the power at least 6 hours before operating the unit in order to ensure smoother operation As soon as the power is turned on the remote controller displays appear 8 ...

Page 8: ...is heard when the system stops after heating operation Expansion and contraction of plastic parts caused by temperature change make this noise A low sah choro choro sound is heard while the indoor unit is stopped When the other indoor unit is in operation this noise is heard In order to prevent oil and refrigerant from remaining in the system a small amount of refrigerant is kept flowing Symptom 8...

Page 9: ...al years performance of the unit will deteriorate to some extent As taking apart and cleaning interiors of units requires technical expertise and in order to ensure the best possible maintenance of your units we recommend to enter into a maintenance and inspection contract on top of normal maintenance activities Our network of dealers has access to a permanent stock of essential components in orde...

Page 10: ...ur dealer for removing and reinstalling the total unit Moving units requires technical expertise This unit uses hydrofluorocarbon Contact your dealer when discarding this unit It is required by law to collect transport and discard the refrigerant in accordance with the hydrofluorocarbon collection and destruction regulations NOTES Component Inspection cycle Maintenance cycle replacements and or re...

Page 11: ...NOTES NOTES ...

Page 12: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW28160 1A ...

Reviews: