4 About the units and options
Installer reference guide
8
(A)RXP20~3 RXF20~35A2V1B
R32 split series
4P513661-2 – 2017.11
1
2
3.2.2
To remove the accessories from the
outdoor unit
1
Lift the outdoor unit.
CAUTION
Only handle the outdoor unit as follows:
2
Remove the accessories at the bottom of the package.
b
e
c
d
1×
a
1×
1×
1×
1×
a
General safety precautions
b
Outdoor unit installation manual
c
Fluorinated greenhouse gases label
d
Multilingual fluorinated greenhouse gases label
e
Drain plug (located on the bottom of the packing case)
4
About the units and options
4.1
Overview: About the units and
options
This chapter contains information about:
▪ Identification of the outdoor unit
4.2
Identification
NOTICE
When installing or servicing several units at the same time,
make sure NOT to switch the service panels between
different models.
4.2.1
Identification label: Outdoor unit
Location
5
Preparation
5.1
Overview: Preparation
This chapter describes what you have to do and know before going
on-site.
It contains information about:
▪ Preparing the installation site
▪ Preparing the refrigerant piping
▪ Preparing the electrical wiring
5.2
Preparing the installation site
Do NOT install the unit in places often used as work place. In case
of construction works (e.g. grinding works) where a lot of dust is
created, the unit MUST be covered.
Choose an installation location with sufficient space for carrying the
unit in and out of the site.