• Split Sky Air • Indoor Units

15

• Indoor Units • R-410A • FTXL-G2V1B

6

Sound data

6 - 1

Sound pressure spectrum

1

6

3D059557A

NOTES

1

220-240V 50 

Hz 

: 50 Hz 220-240V (H)
: 50 Hz 220-240V (L)

Cooling

2

Measure in anechoic room

3

Location of microphone

4

Operation noise differs with operation and ambient conditions.

O

ctave band 

sound 

pr

essu

re

 le

ve

l  

  dB(0dB=0.

00

02μbar)

Approximate 

threshold hearing 

for continuous 

noise

FTXL20G

COOLING

Octave band center frequency (Hz)

1m

0.

8m

3D059557A

NOTES

1

220-240V 50 

Hz 

 

: 50 Hz 220-240V (H)
: 50 Hz 220-240V (L)

Heating

2

Measure in anechoic room

3

Location of microphone

4

Operation noise differs with operation and ambient conditions.

O

ctave band 

sound 

pr

essu

re

 le

ve

l  

  dB(0dB=0.

00

02μbar)

Approximate 

threshold hearing 

for continuous 

noise

FTXL20G

HEATING

Octave band center frequency (Hz)

1m

0.

8m

3D059558A

NOTES

1

220-240V 50 

Hz 

: 50 Hz 220-240V (H)
: 50 Hz 220-240V (L)

Cooling

2

Measure in anechoic room

3

Location of microphone

4

Operation noise differs with operation and ambient conditions.

O

ctave band 

sound 

pr

essu

re

 le

ve

l  

  dB(0dB=0.

00

02μbar)

Approximate 

threshold hearing 

for continuous 

noise

FTXL25G

COOLING

Octave band center frequency (Hz)

1m

0.

8m

3D059558A

NOTES

1

220-240V 50 

Hz 

: 50 Hz 220-240V (H)
: 50 Hz 220-240V (L)

Heating

2

Measure in anechoic room

3

Location of microphone

4

Operation noise differs with operation and ambient conditions.

O

ctave band 

sound 

pr

essu

re

 le

ve

l  

  dB(0dB=0.

00

02μbar)

Approximate 

threshold hearing 

for continuous 

noise

FTXL25G

HEATING

Octave band center frequency (Hz)

1m

0.

8m

Summary of Contents for RXL25G2V1B

Page 1: ... or indirect damage In the broadest sense arising from or related to the use and or interpretation of this publication All content is copyrighted by Daikin Europe N V Daikin Europe N V is participating in the EUROVENT Certification Programme Products are as listed in the EUROVENT Directory of Certified Products Specifications are subject to change without prior notice Naamloze Vennootschap Zandvoo...

Page 2: ...technical data air conditioning systems FTXL G RXL G EEDEN09 003 ...

Page 3: ......

Page 4: ... Sky Air Inverter controlled R 410A RXL G 17 HEAT PUMP 2 PAIR APPLICATION heat pump R 410A FTX 7 WALL MOUNTED UNIT 1 PAGE PAGE I Indoor units pages 7 16 II Outdoor units pages 17 36 L G 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ...

Page 5: ......

Page 6: ...atures 8 2 Specifications 9 For indoor units only 9 Technical Specifications 9 Electrical Specifications 10 3 Dimensional drawing centre of gravity 11 Dimensional drawing 11 Centre of gravity 12 4 Piping diagram 13 5 Wiring diagram 14 Wiring diagram 14 6 Sound data 15 Sound pressure spectrum 15 ...

Page 7: ...ly basis Flat front panel its stylish appearance blends easily within any interior décor and is more easy to clean Comfort mode reassures draught free operation 3D air flow Dual air discharge flow for better air distribution ECONO mode decreases power consumption so that other appliances that need large power supply can be used Indoor outdoor unit silent operation Powerful mode can be selected for...

Page 8: ...ulti louvre Fan Type Cross flow fan Air Flow Rate Cooling High m min 10 4 9 1 10 2 Medium m min 7 7 7 7 8 6 Low m min 4 8 6 3 7 0 Silent Operation m min 3 5 5 4 6 0 Heating High m min 10 6 11 2 11 0 Medium m min 8 5 9 4 9 3 Low m min 6 4 7 7 7 6 Silent Operation m min 5 4 6 8 6 7 Cooling High cfm 367 321 360 Medium cfm 270 273 305 Low cfm 170 221 246 Silent Operation cfm 125 190 212 Heating High c...

Page 9: ...ture control Microcomputer control Standard Accessories Item Titanium apatite photocatalytic air purification filter Quantity 2 2 2 Item Operation manual Quantity 2 2 2 Item Installation manual Quantity 1 1 1 Item Wireless remote control Quantity 1 1 1 Item Batteries Quantity 2 2 2 Item Remote control holder Quantity 1 1 1 Item Indoor unit fixing screws Quantity 2 2 2 Item Mounting plate Quantity ...

Page 10: ...mp Intelligent eye lamp Indoor unit ON OFF switch Room temp thermistor Inside Terminal block with earth terminal Name plate Including mounting plate Up down Automatic FTXL35G 3D058920A Air flow Indoor The mark shows piping direction 50 Min Space for maintenance Space for maintenance 50 Min REQUIRED SPACE 30 Min Space for performance Gas pipe Ø12 7 CuT The length of pipe outside the unit about 350 ...

Page 11: ... Indoor Units R 410A FTXL G2V1B Split Sky Air Indoor Units 12 3 Dimensional drawing centre of gravity 3 2 Centre of gravity 1 3 FTXL20 35G 4D059112A ...

Page 12: ...changer Thermistor on heat exch Fan motor Cross flow fan Field piping Field piping 9 5CuT 9 5CuT 6 4CuT Refrigerant flow Cooling Heating 6 4CuT FTXL35G 4D058898A INDOOR UNIT Heat exchanger Thermistor on heat exch Fan motor Cross flow fan Field piping Field piping 9 5CuT 12 7CuT 6 4CuT Refrigerant flow Cooling Heating 6 4CuT ...

Page 13: ...ng motor Printed circuit board Thermistor Connector Operation switch Terminal switch Protective earth RECTIFIER TRANSMISSION CIRCUIT WIRING DIAGRAM FG F1U H1P H3P M1F M1S M3S PCB1 PCB4 R1T R2T S1 S49 S1W X1M CAUTION Note that operation will restart automatically if the main power supply is turned off and than back on again FIELD WIRING INDOOR INTELLIGENT EYE SENSOR SIGNAL RECEIVER OUTDOOR ...

Page 14: ...ave band sound pressure level dB 0dB 0 0002μbar Approximate threshold hearing for continuous noise FTXL20G HEATING Octave band center frequency Hz 1m 0 8m 3D059558A NOTES 1 220 240V 50 Hz 50 Hz 220 240V H 50 Hz 220 240V L Cooling 2 Measure in anechoic room 3 Location of microphone 4 Operation noise differs with operation and ambient conditions Octave band sound pressure level dB 0dB 0 0002μbar App...

Page 15: ...ave band sound pressure level dB 0dB 0 0002μbar Approximate threshold hearing for continuous noise FTXL35G COOLING Octave band center frequency Hz 1m 0 8m 3D059559A NOTES 1 220 240V 50 Hz 50 Hz 220 240V H 50 Hz 220 240V L Heating 2 Measure in anechoic room 3 Location of microphone 4 Operation noise differs with operation and ambient conditions Octave band sound pressure level dB 0dB 0 0002μbar App...

Page 16: ...minal Input 19 Technical Specifications 19 Electrical Specifications 21 3 Electrical data 22 4 Capacity tables 24 Cooling capacity tables 24 5 Dimensional drawing centre of gravity 27 Dimensional drawing 27 Centre of gravity 28 6 Piping diagram 30 7 Wiring diagram 32 Wiring diagram 32 8 Sound data 34 Sound pressure spectrum 34 9 Operation range 36 ...

Page 17: ...nt full range A class energy labels COP 4 58 EER 4 55 High heating capacity up to 6 6 kW Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall Outdoor units are fitted with a swing compressor renowned for its low noise and high energy efficiency ...

Page 18: ... 17 700 20 500 22 500 Kcal h 4 470 5 160 5 680 Power Input Cooling Minimum kW 0 35 0 44 0 44 Standard kW 0 45 0 55 0 87 Maximum kW 1 19 2 23 1 81 Heating Minimum kW 0 34 0 40 0 40 Standard kW 0 59 0 77 0 92 Maximum kW 1 46 1 98 2 01 For combination indoor units outdoor units EER Nominal 4 44 4 55 4 02 COP Nominal 4 58 4 42 4 35 Energy Label Cooling A Heating A Annual energy consumption kWh 225 275...

Page 19: ...Max CWB 20 20 20 Sound Level nominal Cooling Sound Power dBA 63 63 62 Sound Pressure Low dBA 44 44 44 Sound Pressure High dBA 48 48 48 Heating Sound Pressure Low dBA 45 45 45 Sound Pressure High dBA 48 48 48 Refrigerant Type R 410A Charge kg 1 2 1 3 1 7 Refrigerant Oil Type FVC50K Charged Volume l 0 375 0 650 0 650 Piping connections Liquid OD Diameter OD mm 6 35 6 35 6 35 Gas Diameter OD mm 9 52 ...

Page 20: ...hase 1 Frequency Hz 50 50 50 Voltage V 220 230 240 Current Nominal running current RLA Cooling A A 2 38 2 28 2 19 2 99 2 89 2 80 3 98 3 78 3 59 Heating A A 2 97 2 87 2 78 4 16 3 96 3 77 4 15 3 96 3 76 Starting current cooling heating A 4 8 7 4 7 3 Wiring connections For Power Supply Quantity 3 3 3 For connection with indoor Quantity 4 4 4 Remark including earth wiring ...

Page 21: ...mum allowable voltage variation between phases is 2 3 Select wire size based on the larger value of MCA 4 Instead of fuse use Circuit Breaker RXL25G Representative unit combination Power supply Comp OFM IFM Indoor unit Outdoor unit Hz volts Voltage range MCA MFA RHz RLA W FLA W FLA FTXL25G2V1B RXL25G2V1B 50 220 50 230 50 240 Max 50Hz 264V Min 50Hz 198V 14 75 20 27 5 3 0 50 0 23 23 0 15 2 9 2 8 3D0...

Page 22: ...198V 19 75 20 44 4 0 53 0 27 23 0 15 3 8 3 6 3D059718A SYMBOLS MCA Min Circuit Amps A MFA Max Fuse Amps A RHz Rated operating frequency Hz RLA Rated Load Amps A OFM Outdoor Fan Motor IFM Indoor Fan Motor FLA Full Load Amps A W Fan Motor Rated Output NOTES 1 RLA is based on the following conditions Indoor temp 27 CDB 19 0 CWB Outdoor temp 35 CDB 2 Maximum allowable voltage variation between phases ...

Page 23: ...temp C EDB Entering dry bulb temp C TC Total capacity kW SHC Sensible heating capacity kW PI Power input kW NOTES 1 Capacities are based on the following conditions Corresponding refrigerant piping length 5 m Level difference 0 m 2 shows nominal rated capacities and power input 3 Ratings shown are net capacities which include a deduction for indoor fan motor heat 4 TC PI and SHC must be calculated...

Page 24: ...temp C EDB Entering dry bulb temp C TC Total capacity kW SHC Sensible heating capacity kW PI Power input kW NOTES 1 Capacities are based on the following conditions Corresponding refrigerant piping length 5 m Level difference 0 m 2 shows nominal rated capacities and power input 3 Ratings shown are net capacities which include a deduction for indoor fan motor heat 4 TC PI and SHC must be calculated...

Page 25: ...temp C EDB Entering dry bulb temp C TC Total capacity kW SHC Sensible heating capacity kW PI Power input kW NOTES 1 Capacities are based on the following conditions Corresponding refrigerant piping length 5 m Level difference 0 m 2 shows nominal rated capacities and power input 3 Ratings shown are net capacities which include a deduction for indoor fan motor heat 4 TC PI and SHC must be calculated...

Page 26: ...oor air thermistor Brand name label 4 x holes for anchor bolts M8 or M10 Manufacturer s label In case of removing stop valve cover Drain Pan Heater Assy 3D062702 RXL35G unit mm Minimum space for air passage Wall height on air outlet side less than 1200 Drain outlet I D J 15 9 hose for connection Wiring inlet Gas stop valve J 12 7 CuT Liquid stop valve J 6 4 CuT Service port Outdoor air temperature...

Page 27: ... Outdoor Units R 410A RXL G2V1B Split Sky Air Outdoor Units 28 5 Dimensional drawing centre of gravity 5 2 Centre of gravity 2 5 RXL20G 4D056351G RXL25G 4D059009B ...

Page 28: ... Split Sky Air Outdoor Units 29 Outdoor Units R 410A RXL G2V1B 5 Dimensional drawing centre of gravity 5 2 Centre of gravity 2 5 RXL35G 4D051638K The position of foundation bolt ...

Page 29: ... Flow 6 4 CuT 6 4 CuT 4 8 CuT 4 8 CuT Heat exchanger Thermistor 9 5 CuT 9 5 CuT 7 5 CuT 7 5 CuT Discharge pipe Thermistor Accumulator ø 4 0 x ID 2 OCuT RXL25G 3D059590A 9 5 CuT 9 5 CuT Propeller Fan Muffler Four way valve On Heating Muffler Gas Stop Valve Field Piping Refrigerant Flow Cooling Heating Muffler With Filter Outdoor Air Temperate Thermistor Heat exchanger Outdoor Unit Compressor Heat E...

Page 30: ...d stop valve Field piping Field piping Gas stop valve with service port Compressor Refrigerant flow Cooling Heating Discharge pipe thermistor Heat exchanger thermistor Motor operated valve Capillary tube 1 Outdoor unit Muffler Muffler Four way valve on heating Accumulator Muffler with filter Muffler Filter Receiver Capillary tube 2 Capillary tube 3 Capillary tube 4 ...

Page 31: ...s Drain pan Heater 1 size length 105 x width 185 2 Refer to purchasing specification AS303002 unless otherwise specified 3 This drawing was drawn on CAD system 3D062388 RXL25G R Protective earth C74 C75 C94 C95 Capacitor DB1 DB2 DB3 Diode bridge FU1 FU2 FU3 FU4 FU5 Fuse IPM1 Intelligent power module L Live L1 Coil L1R Reactor M1C Compressor motor M1F Fan motor MRCW MRM10 MRM20 Magnetic relay N Neu...

Page 32: ...U V W X11A E1 E2 HR1 HR2 S2 S102 Connector LEDA Pilot lamp SW1 Forced operation on off SW SW1 SW4 Local setting SW SW4 g Field wiring Indoor Outdoor outdoor Condenser discharge SA1 Surge arrester V2 V3 V5 V6 V11 Varistor X1M X2M Terminal strip Y1E Electronic expansion valve coil Y1R Reversing solenoide valve coil Z1C Z5C Ferrite core Q31 IGBT S1T Thermostat E1H Heater Sheet metal Terminal strip fi...

Page 33: ...ns Octave band sound pressure level dB 0dB 0 0002μbar Approximate threshold hearing for continuous noise RXL20G HEATING Octave band center frequency Hz 1m 3D059597A NOTES 1 Operating conditons 50 Hz 220 240V dB Overall dB Cooling 2 Measure in anechoic room 3 Location of microphone 4 Operation noise differs with operation and ambient conditions Octave band sound pressure level dB 0dB 0 0002μbar App...

Page 34: ...tions Octave band sound pressure level dB 0dB 0 0002μbar Approximate threshold hearing for continuous noise RXL35G COOLING Octave band center frequency Hz 3D059740A NOTES 1 Operating conditons 50 Hz 220 240V dB Overall dB Heating 2 Measure in anechoic room 3 Location of microphone 4 Operation noise differs with operation and ambient conditions Octave band sound pressure level dB 0dB 0 0002μbar App...

Page 35: ...9 RXL20 35G 3D062728 Outdoor temp CDB Pull down period Indoor temp CWB Notes The graphs are based on the following conditions Equivalent piping length 5 m Level difference 0 m Air flow rate high Cooling Heating Indoor temp CDB Outdoor temp CWB Continuous operation Continuous operation ...

Reviews: