![background image](http://html1.mh-extra.com/html/daikin/rx18n5vl/rx18n5vl_removal-procedure_2459901013.webp)
Si001419E
PCB
Removal Procedure
11
4. PCB
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Pull out the 3 terminals
from the terminal board.
Before pulling out the
terminals, confirm the
terminal locations.
(1): black (front)
(2): white (front)
(3): red (front)
2
Pull out the clamp (1)
and cut the clamp (2).
3
Remove the earth /
ground screw.
(3)
(2)
(1)
(R20930)
Clamp (2)
Clamp (1)
(R20931)
Earth / ground screw