Si001555EC
Compressor
Removal Procedure
23
2
Remove the terminal
cover.
3
4
Remove the protection
bushing.
Disconnect the
compressor lead wires
and the overload
protector.
5
6
7
8
Heat up the brazed part
of the discharge side
pipe and disconnect it.
Heat up the brazed part
of the suction side pipe
and disconnect it.
Remove the 3 nuts.
Lift up the compressor
and remove it.
Step
Procedure
Points
Terminal cover
(R21992)
Protection bushing
Overload
protector
V (yellow)
W (blue)
U (red)
(R21993)
Brazed part of the
discharge side pipe
Brazed part of the
suction side pipe
Compressor
Nut
(R22759)