• Split Sky Air • Outdoor Units
11
• Outdoor Units • R-410A • RX-JV/GV
4
Capacity tables
4 - 1
Cooling/Heating capacity tables
FTRX50G2V1B
3D051923C
C
ooling
50Hz
22
0-
2
40
V
AFR
14.7
BF
0.
2
8
Indoor
Outdoor tem
p
erature (°
C
DB)
E
W
B
EDB
2
0
2
5
30
3
2
35
40
°
C
°
C
T
C
SH
C
P
I
T
C
SH
C
P
I
T
C
SH
C
P
I
T
C
SH
C
P
I
T
C
SH
C
P
I
T
C
SH
C
P
I
14.0
16.0
18.0
1
9
.0
22
.0
2
4.0
2
0
22
2
5
2
7
30
3
2
5.1
2
5.35
5.58
5.70
6.04
6.
2
7
3.61
3.55
3.6
9
3.86
3.71
3.60
1.1
9
1.
2
0
1.
2
0
1.
2
1
1.
22
1.
22
4.8
9
5.1
2
5.35
5.47
5.81
6.04
3.4
9
3.43
3.58
3.75
3.6
2
3.5
2
1.30
1.31
1.3
2
1.3
2
1.33
1.34
4.66
4.8
9
5.1
2
5.
2
3
5.58
5.81
3.37
3.3
2
3.47
3.65
3.5
2
3.43
1.4
2
1.43
1.43
1.44
1.45
1.45
4.56
4.7
9
5.0
2
5.14
5.4
9
5.7
2
3.3
2
3.
2
7
3.43
3.61
3.4
9
3.40
1.46
1.47
1.48
1.48
1.4
9
1.50
4.4
2
4.65
4.88
3.
2
5
3.
2
1
3.37
1.53
1.54
1.55
4.1
9
4.4
2
4.65
4.77
5.11
5.34
3.13
3.10
3.
2
6
3.45
3.35
3.
2
7
1.65
1.65
1.66
1.66
1.67
1.68
5.00
3.55
1.55
5.35
5.58
3.43
3.35
1.56
1.57
Heating
50Hz
22
0-
2
40
V
AFR
16.1
Indoor
Outdoor tem
p
erature (°
C
W
B)
EDB
-10
-5
0
6
10
°
C
T
C
P
I
T
C
P
I
T
C
P
I
T
C
P
I
T
C
P
I
15.0
2
0.0
22
.0
2
4.0
2
5.0
2
7.0
3.
9
0
3.70
3.6
2
3.54
3.50
3.4
2
1.35
1.3
9
1.40
1.4
2
1.43
1.44
4.56
4.36
4.
2
8
4.
2
0
4.16
4.08
1.4
2
1.46
1.47
1.48
1.4
9
1.51
5.
2
1
5.01
4.
9
3
4.85
4.81
4.73
1.48
1.5
2
1.54
1.55
1.56
1.57
6.00
1.56
6.5
2
6.3
2
6.
2
4
6.16
6.1
2
6.04
1.6
2
1.65
1.67
1.68
1.6
9
1.70
5.80
1.60
5.7
2
5.64
5.60
5.5
2
1.61
1.63
1.64
1.65
NOTES
1.
Ratings shown are net ca
p
acities which include a
deduction for indoor fan motor heat.
2
.
shows nominal (rated) ca
p
acities and
p
ower in
p
ut.
3.
T
C
,
P
I and SH
C
must be calculated by inter
p
olation using
the figures in the abo
v
e tables. (Figures out of the tables
should not be used for calculation.)
4.
About SH
C
which are not mentioned on the table,
p
lease
calculate them with around
v
alues in direct
p
ro
p
ortion.
5.
C
a
p
acities are based on the following conditions.
C
orres
p
onding refrigerant
p
i
p
ing length : 7.5m
Le
v
el difference
: 0m
6.
Air flow rate (AFR) and By
p
ass factor (BF) are tabulated
abo
v
e table.
SYMBOLS
AFR
: Air flow rate
(m
3
/min.)
BF
: By
p
ass factor
E
W
B
: Entering wet bulb tem
p
. (°
C
)
EDB
: Entering dry bulb tem
p
.
(°
C
)
T
C
: Total ca
p
acity
(k
W
)
SH
C
: Sensible heat ca
p
acity
(k
W
)
P
I
:
P
ower in
p
ut
(k
W
)
RX-JV-GV_EN.pdf 13
12/05/2010 8:21:50