7.7.2
Values
[→ Main menu → Information → Values]
Parameters
Unit
Description
Factory
setting
Incre-
ment
Access
BE
HF
Feed temper-
ature, current
°C
The current feed temperature of the heat generator (t
V1
) is displayed in °C.
-
1 °C
S
S
Feed temper-
ature, target
°C
The current target temperature of the heat generator is displayed in °C.
-
0.1 °C
S
S
Average out-
side temperat-
ure
°C
The current outside temperature is displayed in °C.
0.1 °C
S
S
Hot water tem-
perature, cur-
rent
°C
The current temperature of the hot water storage tank is displayed in °C. If
no hot water function is activated, "----" is displayed.
-
0.1 °C
S
S
Hot water tem-
perature, tar-
get
°C
The current target temperature for domestic hot water preparation is dis-
played in °C. If no hot water function is activated, "----" is displayed. Here,
the current target value is always the maximum value of all requests relev-
ant for this hot water circuit.
-
0.1 °C
S
S
Return flow
temperature
°C
The current return flow temperature of the heat generator is displayed in
°C. If no respective sensor is connected to the heat generator, "----" is dis-
played.
-
0.1 °C
S
S
Feed temper-
ature HC cur-
rent
°C
The temperature of the direct HC (t
V2
is displayed with active heating sup-
port, otherwise t
V1
) in °C.
-
0.1 °C
S
S
Feed temper-
ature HC tar-
get
°C
The (feed) target temperature of the direct HC is displayed in °C.
-
0.1 °C
S
S
Feed temper-
ature PHX
°C
The current feed temperature of the heat generator in the outdoor unit is
displayed.
-
0.1 °C
S
S
Feed temper-
ature BUH
°C
The current feed temperature of the heat generator after the optional
backup heater is displayed.
-
0.1 °C
S
S
Outdoor tem-
perature (op-
tional)
°C
The current outdoor temperature measured by the optional outdoor tem-
perature sensor is displayed.
-
0.1 °C
S
S
Refrigerant
temperature
°C
The current refrigerant temperature of the outdoor unit (liquid) is displayed.
-
0.1 °C
S
S
Volume flow
l/h
The filtered value of the current water-side volume flow is displayed.
If glycol is added and the internal flow switch is active, 0 l/h is displayed.
-
1 l/h
S
S
Water pres-
sure
bar
The current water pressure is displayed.
-
0.1 bar
S
S
Tab. 7-20
Parameter in the "Values" menu
INFORMATION
Depending on the device type, the system configuration
and the status of the device software, individual listed in-
formation parameters cannot be displayed or can be dis-
played at a different parameter level.
7.7.3
Water pressure
[→ Main menu → Information → Pressure]
Parameters
Unit
Description
Factory
setting
Incre-
ment
Access
BE
HF
Water pres-
sure
bar
The current water pressure is displayed in bar.
-
0.1 bar
S
S
Tab. 7-21
Parameter in the "Water pressure" menu
Summary of Contents for RoCon+ HP Series
Page 116: ...Betriebsanleitung 116 Daikin RoCon HP Daikin Regelung RoCon HP1 008 1447899_00 09 2019 DE ...
Page 236: ...Gebruiksaanwijzing 236 Daikin RoCon HP Daikin regeling RoCon HP1 008 1447899_00 09 2019 NL ...
Page 351: ...Driftsvejledning 351 Daikin RoCon HP Daikin regulering RoCon HP1 008 1447899_00 09 2019 DA ...
Page 406: ...Instruktionsbok 406 Daikin RoCon HP Daikin reglerenhet RoCon HP1 008 1447899_00 09 2019 SV ...
Page 460: ...Brukerveiledning 460 Daikin RoCon HP Daikin Regulering RoCon HP1 008 1447899_00 09 2019 NO ...
Page 516: ...008 1447899_00 09 2019 EN DE FR NL IT DA SV NO FI Copyright Daikin ...