Operating instructions
8
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3
x
Operation
3
Operation
3.1
General
3.2
Display and operating elements
3.2.1 Display
All operating steps are supported by corresponding displays on a
coloured backlit plain text display.
The menu guidance can be displayed 7 languages (see
chap. 3.4.8).
The colour of the backlighting indicates the operational status
and the operating mode:
DANGER!
If electrical components come into
contact
with
water
, this can cause an
electric shock
as well
as cause potentially fatal burns or injuries.
●
The
displays and
the
keys
of the control unit
must be protected
against
the effects of
moisture
.
●
To
clean
the control unit, use a
dry cotton
cloth
. Using aggressive
cleaning agents
and other
liquids
can cause
damage to
equipment or lead to an electric shock
.
1
Clear text display
2
Setting: Configuration
3
Setting: Remote Param
4
Rotary switch
5
Setting: Info
6
Setting: Operating Mode
7
Setting: Set Temp Day
8
Setting: Set Temp Night
9
Setting: DHW Set Temp
10
Rotary button
11
Setting: DHW Reheating
12
Setting: Time Program
13
Exit key
Fig. 3-1
Arrangement of display and operating elements
Faults are generally indicated by an error code and a
clear text error message on the display.
For troubleshooting instructions, see chap. 7.
White:
Standard lighting, normal operating display.
Red:
Error status; depending on the type of error, the
Daikin heat generator continues to operate with
restrictions.
Green:
Operating mode with operator authorisation.
Blue:
Operating mode with expert authorisation.
1
Display date
2
Burner activity status
3
Expert login display
4
Time display
5
Current T-HS
6
Heating circuit status
7
Current outside temperature
8
Active operating mode
9
Hot water generation status
10
Current storage temperature
Fig. 3-2
Display of the control unit - standard display
Item
Icon
Explanation
2
Heat requirement active
3
Expert access rights active (see
chap. 3.6.1)
2 / 3
Air purge active (see chap. 3.6.4)
2 / 3
Terminal function active (see chap. 3.4.9)
2 / 3
Frost protection function active (see
chap. 3.6.11)
2 / 3
Temporary time program "Party" active (see
chap. 3.4.7)
2 / 3
Temporary time program "Away" active
(see chap. 3.4.7)
2 / 3
Temporary time program "Holiday" active
(see chap. 3.4.7)
2 / 3
Temporary time program "Vacation" active
(see chap. 3.4.7)
2 / 3
Screed program active (see chap. 3.6.7)
5
Direct heating circuit
– During normal operation, the current T-
HS t
V1
is displayed underneath.
5
Mixer circuit
The current T-HS of the assigned heating
circuit is displayed underneath.