background image

10

9

Indoor unit

Outdoor unit

See page 7

See page 5

See page 6

See page 8

See page 8

See page 7

See page 4

See page 4

See page 7

See page 4

See page 7

Comfortable Airflow

Comfort Control

Lifestyle Convenience

Cleanliness

Timers

Worry Free

Power-Airflow Dual Flaps can flatten out during cooling 
operation to deliver cool air to the corners of a room. 

The microprocessor automatically controls fan speed to 
adjust the room temperature to the set temperature.

This function automatically reduces the level of humidity.

The unit can be conveniently started manually in the 
event the wireless remote controller is misplaced or the 
wireless remote controller batteries are not charged.

The flat panel models can be cleaned with only the single 
pass of a cloth across their smooth surface. The flat panel 
can also be easily removed for more thorough cleaning.

This timer can be preset to start and stop at any time 
within a 24-hour period. The air conditioner is 
started/stopped simply by pressing the On/Off/setting 
timer button on the wireless remote controller.

Pressing the Off timer button automatically selects Night 
Set Mode. Room temperature is raised by 0.5  C after 60 
minutes to prevent excessive cooling for your pleasant 
sleep.

The air conditioner memorises the settings for mode, 
airflow, temperature, etc., and automatically returns to 
them when power is restored after a power failure.

Malfunction codes are shown on the digital display panel 
of the wireless remote controller for fast and easy 
maintenance.

The outdoor unit’s heat exchanger fins are processed 
using a special anticorrosion treatment. The surface is 
covered with a thin acrylic resin layer to enhance the fins’ 
resistance to acid rain and salt corrosion. 

This filter traps microscopic particles, decomposes 
odours and even removes bacteria and viruses. It can be 
used for up to 3 years .

Power-Airflow Dual Flaps

Auto Fan Speed

Programme Dry Function

Indoor Unit On/Off Switch

24-Hour On/Off Timer

Night Set Mode

Auto-Restart After Power Failure

Self-Diagnosis with Digital Display

Anticorrosion Treatment of Outdoor Heat 

Exchanger Fins

Wipe-Clean Flat Panel

Air-Purifying Filter with Photocatalytic 
Deodorising Function

Notes: *1. The filter is a standard accessory. It should be replaced after approximately every 3 years.

Measurement conditions
1. Cooling capacity is based on: indoor temp. 27   CDB, 19   CWB; outdoor temp. 35   CDB; piping length 7.5 m.
2. Sound levels are based on temperature condition in 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual 

opration as a result of ambient conditions.

Specifications are subject to change.

No.

1
2

Item 

Air-purifying filter with photocatalytic deodorising function without frame
Remote controller loss prevention with chain

FTN50/60JV1

*

1

Air-purifying filter with photocatalytic 
deodorising function without frame
KAF952A42

Remote controller loss 

prevention with chain
KKF917A4

kW

Btu/h

A

W

W/W

mm

m

W
kg

dB (A)

kg

mm

dB (A)

mm

kg

1 phase, 220-240 V, 50Hz

 
 
 
 

White

 

5 steps and automatic

 

290 x 1,050 x 238

12 

 

Ivory white

Hermetically sealed rotary type

 
 

 

19.4 to 46 

  6.4

 

  18.0

30
20

Capacity

Power supply
Running current
Power consumption
COP

Front panel colour
Airflow rate (H)
Fan speed
Sound levels (H/L)
Dimensions (H x W x D)
Machine weight 

Casing colour

Compressor

Refrigerant charge (R-410A)

Dimensions (H x W x D)
Machine weight
Operation range

Piping connections

Max. piping length

Type

Motor output

Liquid

Gas

Drain

5.3

18,090

7.5

1,640

3.23

FTN50JV1

17.5 (618)

45/35

RN50JV1

1,300

1.6

50

735 x 825 x 300

48

  12.7

6.7

22,860

10.2

2,210

3.03

FTN60JV1

18.5 (653)

47/36

RN60JV1

1,700

2.0

52

770 x 900 x 320

63

  15.9

Sound levels 

Max. height difference

Model name

FTN50JV1

RN50JV1

Indoor unit

Outdoor unit

FTN60JV1

RN60JV1

Indoor unit

Outdoor unit

 CDB

m

3

/min (cfm)

KAF952A42

KKF917A4

No.

1
2

Item 

Air direction adjustment grille
Drain plug

RN50/60JV1

KPW945A4

KKP937A4

The smoothly curved Wide-Angle Louvres provide wide 
airflow coverage for effective operation no matter where 
the indoor unit is placed in a room. 

This function automatically moves the flaps up and down 
to distribute air across a room.

Horizontal Auto-Swing automatically moves the louvres 
to the left and right to cover a room with cool air.

New Powerful Operation boosts airflow to maximum   
volume for a 20-minute period. After this, the unit 
automatically returns to its previous settings.

This function combines Vertical and Horizontal Auto-
Swing to circulate a cloud of cool air right to the corners 
of even large spaces.

Note: The above values are based on operation with a 220V, 50Hz power supply.

Wide-Angle Louvres

Vertical Auto-Swing (up and down)

Horizontal Auto-Swing (left and right)

New Powerful Operation

3-D Airflow

Summary of Contents for RN50JV1

Page 1: ...05 Y K P C c Dealer Head Office Umeda Center Bldg 2 4 12 Nakazaki Nishi Kita ku Osaka 530 8323 Japan Tokyo Office JR Shinagawa East Bldg 2 18 1 Konan Minato ku Tokyo 108 0075 Japan http www daikin com global_ac Specifications designs and other content appearing in this brochure are current as of June 2010 but subject to change without notice 1 Air conditioners should not be installed in areas wher...

Page 2: ... of 3 23 A high COP is important for energy efficiency Vertical and Horizontal Auto Swing plus other airflow functions give you more comfortable airflow Air Purifying Filter with Photocatalytic Deodorising function traps dust decompose odours and even removes bacteria and viruses ...

Page 3: ...Btu h The stylish flat panel design creates a simplicity and sophistication that enhances any interior space FTN series offer 5 0 and 6 0 kW models that are appropriate for spacious rooms as living rooms FTN50 60J RN60J RN50J Vertical Auto Swing automatically moves the flaps up and down and Horizontal Auto Swing automatically moves the louvres to the left and right 3 D Airflow combines Vertical an...

Page 4: ...organisation Japan Spinners Inspecting Foundation Result certificate No 012553 1 and 012553 2 Based on Examples of Sound Levels Ministry of the Environment Japan November 12 2002 This filter is not a medical devices Benefits such as the adsorption and decomposition of bacteria and viruses are only effective for substances that are collected on and in direct contact with the Air Purifying Filter wi...

Page 5: ...g operation no matter where the indoor unit is placed in a room The louvers can be adjusted by hand Covers even a spacious room From a corner to the centre Cool air slides off to reach the corner of the room Selects fan speed Selects mode cooling dry fan only operation Cancels On Off Timer 24 Hour On Timer 24 Hour Off Timer and Night Set Mode Sets timer Sets clock On Off switch Sets room temperatu...

Page 6: ...approximately every 3 years Measurement conditions 1 Cooling capacity is based on indoor temp 27 CDB 19 CWB outdoor temp 35 CDB piping length 7 5 m 2 Sound levels are based on temperature condition in 1 above These are anechoic conversion values These values are normally somewhat higher during actual opration as a result of ambient conditions Specifications are subject to change No 1 2 Item Air pu...