10
9
Indoor unit
Outdoor unit
See page 7
See page 5
See page 6
See page 8
See page 8
See page 7
See page 4
See page 4
See page 7
See page 4
See page 7
Comfortable Airflow
Comfort Control
Lifestyle Convenience
Cleanliness
Timers
Worry Free
Power-Airflow Dual Flaps can flatten out during cooling
operation to deliver cool air to the corners of a room.
The microprocessor automatically controls fan speed to
adjust the room temperature to the set temperature.
This function automatically reduces the level of humidity.
The unit can be conveniently started manually in the
event the wireless remote controller is misplaced or the
wireless remote controller batteries are not charged.
The flat panel models can be cleaned with only the single
pass of a cloth across their smooth surface. The flat panel
can also be easily removed for more thorough cleaning.
This timer can be preset to start and stop at any time
within a 24-hour period. The air conditioner is
started/stopped simply by pressing the On/Off/setting
timer button on the wireless remote controller.
Pressing the Off timer button automatically selects Night
Set Mode. Room temperature is raised by 0.5 C after 60
minutes to prevent excessive cooling for your pleasant
sleep.
The air conditioner memorises the settings for mode,
airflow, temperature, etc., and automatically returns to
them when power is restored after a power failure.
Malfunction codes are shown on the digital display panel
of the wireless remote controller for fast and easy
maintenance.
The outdoor unit’s heat exchanger fins are processed
using a special anticorrosion treatment. The surface is
covered with a thin acrylic resin layer to enhance the fins’
resistance to acid rain and salt corrosion.
This filter traps microscopic particles, decomposes
odours and even removes bacteria and viruses. It can be
used for up to 3 years .
Power-Airflow Dual Flaps
Auto Fan Speed
Programme Dry Function
Indoor Unit On/Off Switch
24-Hour On/Off Timer
Night Set Mode
Auto-Restart After Power Failure
Self-Diagnosis with Digital Display
Anticorrosion Treatment of Outdoor Heat
Exchanger Fins
Wipe-Clean Flat Panel
Air-Purifying Filter with Photocatalytic
Deodorising Function
Notes: *1. The filter is a standard accessory. It should be replaced after approximately every 3 years.
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Sound levels are based on temperature condition in 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual
opration as a result of ambient conditions.
Specifications are subject to change.
No.
1
2
Item
Air-purifying filter with photocatalytic deodorising function without frame
Remote controller loss prevention with chain
FTN50/60JV1
*
1
Air-purifying filter with photocatalytic
deodorising function without frame
KAF952A42
Remote controller loss
prevention with chain
KKF917A4
kW
Btu/h
A
W
W/W
mm
m
W
kg
dB (A)
kg
mm
dB (A)
mm
kg
1 phase, 220-240 V, 50Hz
White
5 steps and automatic
290 x 1,050 x 238
12
Ivory white
Hermetically sealed rotary type
19.4 to 46
6.4
18.0
30
20
Capacity
Power supply
Running current
Power consumption
COP
Front panel colour
Airflow rate (H)
Fan speed
Sound levels (H/L)
Dimensions (H x W x D)
Machine weight
Casing colour
Compressor
Refrigerant charge (R-410A)
Dimensions (H x W x D)
Machine weight
Operation range
Piping connections
Max. piping length
Type
Motor output
Liquid
Gas
Drain
5.3
18,090
7.5
1,640
3.23
FTN50JV1
17.5 (618)
45/35
RN50JV1
1,300
1.6
50
735 x 825 x 300
48
12.7
6.7
22,860
10.2
2,210
3.03
FTN60JV1
18.5 (653)
47/36
RN60JV1
1,700
2.0
52
770 x 900 x 320
63
15.9
Sound levels
Max. height difference
Model name
FTN50JV1
RN50JV1
Indoor unit
Outdoor unit
FTN60JV1
RN60JV1
Indoor unit
Outdoor unit
CDB
m
3
/min (cfm)
KAF952A42
KKF917A4
No.
1
2
Item
Air direction adjustment grille
Drain plug
RN50/60JV1
KPW945A4
KKP937A4
The smoothly curved Wide-Angle Louvres provide wide
airflow coverage for effective operation no matter where
the indoor unit is placed in a room.
This function automatically moves the flaps up and down
to distribute air across a room.
Horizontal Auto-Swing automatically moves the louvres
to the left and right to cover a room with cool air.
New Powerful Operation boosts airflow to maximum
volume for a 20-minute period. After this, the unit
automatically returns to its previous settings.
This function combines Vertical and Horizontal Auto-
Swing to circulate a cloud of cool air right to the corners
of even large spaces.
Note: The above values are based on operation with a 220V, 50Hz power supply.
Wide-Angle Louvres
Vertical Auto-Swing (up and down)
Horizontal Auto-Swing (left and right)
New Powerful Operation
3-D Airflow