![Daikin RM13NV2S Service Manual Download Page 14](http://html1.mh-extra.com/html/daikin/rm13nv2s/rm13nv2s_service-manual_4160448014.webp)
Compressor ASSY
Si011357EA
12
Removal Procedure
2
3
Disconnect the
compressor lead wires.
Remove the gasket.
S (W): yellow
C (U): blue
R (V): red
4
Remove the 3 nuts of
the compressor.
5
Heat up the brazed part
of the discharge side
pipe and disconnect it.
Step
Procedure
Points
(R17183)
Gasket
S (W)
C (U)
R (V)
(R15393)
C (U)
R (V)
S (W)
(R20756)
(R15442)
(R20757)
Discharge
side pipe