![Daikin RKS25EBVMV Service Manual Download Page 8](http://html1.mh-extra.com/html/daikin/rks25ebvmv/rks25ebvmv_service-manual_4701497008.webp)
Electrical Box
Si001267EB
6
Removal Procedure
3. Electrical Box
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Disconnect the 2
connectors for the
reactor.
2
Disconnect the
connector [S30].
[S30]: compressor
3
Disconnect the
connector [S40].
[S40]: overload protector
4
Disconnect the
connector [S20].
[S20]:
electronic expansion
valve coil
5
Disconnect the
connector [S80].
[S80]: four way valve coil
The cooling only models
have no harness for [S80].
When reassembling,
connect the connectors in
the following order.
(1) [S80]
(2) [S20]
(3) [S40]
(4) [S30]
(5) reactor
When reassembling, set the
harnesses of the four way
valve coil and electronic
expansion valve coil in front
of the compressor lead wire.
(R17221)
[S30]
Reactor
(R17222)
[S40]
[S20]
(R7219)
[S80]