Removal of Outer Panels / Fan Motor
Si001071
2
Removal Procedure
1. Removal of Outer Panels / Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Appearance features
Take care not to cut your
finger by the fins of the
outdoor heat exchanger.
2. Remove the panels.
The stop valve cover is
united with the shield plate.
When reassembling, make
sure to fit the 5 hooks.
1
Remove the screw of
the stop valve cover.
Pull down the stop
valve cover and remove
it.
(R3235)
(R11890)
Stop
valve
cover
(R3237)
Hooks
(R12421)
Shield plate