Removal of Electrical Box
Si001166
16
Removal Procedure
7
Release the thermistor
harness from the hook
at the bottom of
electrical box.
8
Pull out the clamp of the
thermistor harness from
the hole of the electrical
box.
9
The compressor lead
wire is fixed on the
partition plate (1) with a
clamp.
10
Release the clamp of
the compressor relay
harness with pliers.
Step
Procedure
Points
Fixing position for the
thermistor harness
Hook
(R16647)
When reassembling, insert
the clamp into the small hole.
Clamp
(R16704)
Clamp