Si001654EA
Thermistor ASSY / PCB
Removal Procedure
11
4. Thermistor ASSY / PCB
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Remove the thermistor
ASSY.
1
Pull out the 2 clamps
and push the 2
projections of the
clamps from the back of
the electrical box and
pull them out.
2
Remove the earth/
ground screw.
3
Disconnect the 3
terminals for power
supply.
[HL1], [HN1], [S]: terminal board
Projection of
clamp
Clamp
(R23204)
Earth/ground screw
(R24116)
Top view
[S]
[HL1]
[HN1]
(R23206)