![background image](http://html1.mh-extra.com/html/daikin/rkm46qvma/rkm46qvma_service-manual_4699947011.webp)
Si001654EA
Electrical Box
Removal Procedure
9
4
Disconnect the
connector [S80], pull
out the clamp (1) and
cut the clamp (2).
[S80]: four way valve coil
The cooling only models
have no harness for [S80].
The position of the clamp (1)
varies depending on the
model.
Some models do not have
clamp (2).
When reassembling, fit the
clamps back to the hole to
make sure the wires do not
touch the four way valve.
5
Disconnect the
connector [S40].
[S40]: overload protector
For RX(K)M71QVMA, make
sure the relay connector for
compressor is under the
electrical box.
When reassembling, fit the
clamp back to the hole to
make sure the wires do not
touch the four way valve
pipe.
6
Disconnect the relay
connector for
compressor and pull out
the clamp.
Step
Procedure
Points
[S80]
Clamp (1)
Clamp (2)
(R23197)
[S40]
(R23198)
Electrical box
Relay connector
(R24114)
Four way valve pipe
Clamp
Wire
(R24115)
Relay connector
Clamp
(R23199)