Si001420E
Compressor
Removal Procedure
21
2
3
Remove the protection
bushing.
Disconnect the
compressor lead wires
and the overload
protector.
4
5
6
7
Remove the sheets of
putty, to avoid burning
them.
Heat up and disconnect
the brazed part of the
discharge side pipe.
Heat up and disconnect
the brazed part of the
suction side pipe.
Remove the 2 nuts and
remove the
compressor.
Step
Procedure
Points
W (blue)
Overload
protector
V (yellow)
U (red)
Protection bushing
(R21273)
Brazed part of discharge side
Brazed part
of suction
side
Putty
Putty
Nut
(R21277)