
Si001268E
Electrical Box
Removal Procedure
5
3. Electrical Box
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Disconnect the
connector [S70].
[S70]: fan motor
2
Disconnect the
connector [S40].
[S40]: overload protector
3
Cut the clamp and
disconnect the
connector [S90].
[S90]: thermistors
(R19362)
[S70]
(R18435)
[S40]
(R19363)
(R18436)
Clamp
[S90]