background image

Removal of Compressor

Si011083

10

Removal Procedure

4. Removal of Compressor

Procedure

Warning

Be sure to wait 10 minutes or more after turning off all power supplies 
before disassembling work.

Step

Procedure

Points

1

Remove the 3 nuts of 
the compressor.

Warning

Be careful not to get yourself 
burnt with the pipes and other 
parts that are heated by the 
gas brazing machine.

Warning

If the refrigerant gas leaks 
during work, ventilate the 
room. (If the refrigerant gas is 
exposed to flames, toxic gas 
may be generated.)

Warning

Since it may happen that the 
refrigerant oil in the 
compressor catches fire, 
prepare wet cloth so as to 
extinguish fire immediately.

Caution

From the viewpoint of global 
environment protection, do 
not discharge the refrigerant 
gas in the atmosphere. Make 
sure to collect all the 
refrigerant gas.

Cautions for restoration

1. Restore the piping by non-

oxidation brazing. 

2. It is required to prevent the 

carbonization of the oil inside 
the four way valve and the 
deterioration of the gaskets 
affected by heat. (Keep 
below 120°C.) For the sake 
of this, wrap the four way 
valve with wet cloth and 
provide water so that the 
cloth does not dry.

In case of difficulty with gas 
brazing machine 

1. Disconnect the brazed part 

where is easy to disconnect 
and restore.

2. Cut pipes on the main unit 

with a tube cutter in order to 
make it easy to disconnect.

„

Before working, make 
sure that the refrigerant is 
empty in the circuit.

„

Be sure to apply nitrogen 
replacement when 
heating up the brazed 
part.

2

Heat up the brazed part 
of the discharge side 
and disconnect.

3

Heat up the brazed part 
of the suction side and 
disconnect.

(R6729)

(R6730)

(R6731)

Summary of Contents for RE09LV2S

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Outdoor Unit Non inverter Pair Type 2 5 3 5 kW Class 9000 12000 Btu h Class Si011083...

Page 2: ...Service Manual Removal Procedure Outdoor Unit zCooling Only R25GV1G6 R35GV1G6 RE09LV2S RE12LV2S...

Page 3: ...1 Table of Contents 1 Removal of Outer Panels Fan Motor 2 2 Removal of Electrical Components ASSY 8 3 Removal of Sound Blanket 9 4 Removal of Compressor 10 Note The illustrations may be slightly diffe...

Page 4: ...g work Step Procedure Points 1 External appearance Take care not to cut your finger by the fins of the outdoor heat exchanger 2 Remove the panels The stop valve cover is united with the shield plate W...

Page 5: ...ews and remove the top panel 3 Remove the 4 screws and remove the discharge grille The discharge grille has 4 hooks 4 Remove the 8 screws and remove the front panel Step Procedure Points DAIKIN INVERT...

Page 6: ...M6 1 Remove the nut of the outdoor fan 2 Remove the outdoor fan When reassembling align the mark of the outdoor fan with the D cut section of the motor shaft 3 Disconnect the connector for the fan mo...

Page 7: ...n motor lead wire through the back of the fan motor when reassembling so as not to be entangled with the outdoor fan 5 Remove the 4 screws and remove the fan motor 6 Remove the screw and remove the fa...

Page 8: ...6 Removal Procedure When reassembling fit the lower hooks into the bottom frame 4 Remove the right side panel 1 Lift up and remove the guard net 2 Remove the 2 screws on the rear side Step Procedure...

Page 9: ...e 7 3 Remove the 4 screws on the right side 4 Remove the screw near the connection port 5 Unfasten the hook When reassembling make sure to fit the hook 6 Lift up the right side panel and remove it Ste...

Page 10: ...Step Procedure Points 1 Remove the nut and remove the terminal cover Preparation Remove the outer panels and disconnect the connector for the fan motor according to the Removal of Outer Panels Fan Mo...

Page 11: ...Procedure Points 1 Untie the strings and open the sound blanket Preparation Remove the outer panels according to the Removal of Outer Panels Fan Motor Remove the electrical components ASSY according...

Page 12: ...t discharge the refrigerant gas in the atmosphere Make sure to collect all the refrigerant gas Cautions for restoration 1 Restore the piping by non oxidation brazing 2 It is required to prevent the ca...

Page 13: ...the sawdust comes into the circuit When withdrawing the pipes be careful not to pinch them firmly with pliers The pipes may get deformed Provide a protective sheet or a steel plate so that the brazin...

Page 14: ...Revision History Month Year Version Revised contents 01 2013 Si011083 First edition...

Page 15: ...ies supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acces...

Reviews: