background image

Outer Panels / Fan Motor / Electrical Components

Si011404EC

4

Removal Procedure

2. Remove the fan motor.

„

Nut size: M6

„

Align the 

mark of the 

outdoor fan with the D-cut 
section of the motor shaft 
when reassembling.

1

Remove the nut, and 
then the outdoor fan.

2

Cut the clamp and 
release the fan motor 
lead wire.

3

Pull out the 2 terminals 
(red, white) from the 
capacitor (C1).

„

Capacitor (C1)

4

Pull out the terminal 3 
(front, black) from the 
terminal board (X1M).

„

Terminal board (X1M)

Step

Procedure

Points

Outdoor fan

(R20109)

10 mm 
(0.39 inch)

(R18954)

Clamp

(R20110)

(R20111)

from fan motor: 
red

from fan motor: 
white

(R23473)

(R20112)

Terminal 

board

from fan motor: 
black

(R23474)

Summary of Contents for RC25QRV16

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L 2 5 3 5 kW Class Outdoor Unit Non Inverter Pair Type Si011404EC ...

Page 2: ...F35QRV161 RQ35QRV1625 RC35QRV161 RF35QRV1625 RC35QRV1615 RQ35RRV162 RF35RRV161 RQ35RRV1625 RC25RRV162 RF35RRV1615 RC35RRV161 RQA35QRV16 RC35RRV1615 RFA35QRV16 RQA35RRV162 RCA25QRV16 RFA35RRV161 RCA35QRV16 RQD35QRV16 RFD35QRV16 RCA25RRV162 RQD35RRV162 RCA35RRV161 RFD35RRV161 RUF35RRV161 RCD25QRV16 RCD35QRV16 RCD25RRV162 RCD35RRV161 ...

Page 3: ...ocedure 1 Table of Contents 1 Outer Panels Fan Motor Electrical Components 2 2 Sound Blanket Partition Plate 8 3 Capillary Tube 9 4 Compressor ASSY 10 Note The illustrations may be slightly different depending on the model ...

Page 4: ...more after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the outer panels 1 Remove the screw and then the stop valve cover The stop valve cover is united with the shield plate When reassembling make sure to fit the 5 hooks 2 Remove the 2 screws and then the top panel R20986 Stop valve cover R20987 Hook Hook Top panel R16334 ...

Page 5: ...rews and then the discharge grille The discharge grille has 4 hooks 4 Remove the 7 screws of the front panel 5 Unfasten the 4 hooks and remove the front panel The front panel has 4 hooks Step Procedure Points R16335 Discharge grille Discharge grille R20106 Front panel R20107 Front panel R20108 ...

Page 6: ... nut and then the outdoor fan 2 Cut the clamp and release the fan motor lead wire 3 Pull out the 2 terminals red white from the capacitor C1 Capacitor C1 4 Pull out the terminal 3 front black from the terminal board X1M Terminal board X1M Step Procedure Points Outdoor fan R20109 10 mm 0 39 inch R18954 Clamp R20110 R20111 from fan motor red from fan motor white R23473 R20112 Terminal board from fan...

Page 7: ... outdoor fan When reassembling fit the 2 lower hooks into the bottom frame 6 Remove the screw and then the fan motor fixing frame 7 8 Release the fan motor lead wire from the 2 hooks Remove the 4 screws and then the fan motor 3 Remove the electrical components 1 Remove the screw of the capacitor fixing band Step Procedure Points Hook Groove Fan motor lead wire R22648 R3249 Lead wire Outdoor fan R1...

Page 8: ... the terminal board and disconnect the connecting wire and the power supply wire 5 Remove the 2 screws and then the electrical component mounting plate Step Procedure Points Capacitor R20117 from compressor S red from compressor R blue from terminal 2 blue Capacitor C1 R23475 Wire fixture Wire fixture Power supply wire Connecting wire Terminal board R22649 Electrical component mounting plate R2011...

Page 9: ...ht side panel 1 Remove the 5 screws and remove the right side panel There are 2 hooks on the right side panel When reassembling make sure to fit the 2 hooks Step Procedure Points R20131 Terminal board from capacitor C1 blue from compressor C white earth ground wire green yellow R23476 Terminal board X1M Right side panel R22650 Hook R20121 ...

Page 10: ...tes or more after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the sound blanket Some models have sound blanket top Since the piping ports are torn easily remove the sound blanket s carefully 2 Remove the 2 screws and then the partition plate Sound blanket R20122 Partition plate R20123 ...

Page 11: ...pply nitrogen replacement when heating up the brazed part Do not use a metal saw for cutting pipes by all means because the sawdust comes into the circuit When withdrawing the pipes be careful not to pinch them firmly with pliers The pipes may get deformed Provide a protective sheet or a steel plate so that the brazing flame cannot influence peripheries Be careful so as not to burn the compressor ...

Page 12: ...g by non oxidation brazing Note Before working make sure that the refrigerant gas is empty in the circuit Be sure to apply nitrogen replacement when heating up the brazed part Do not use a metal saw for cutting pipes by all means because the sawdust comes into the circuit When withdrawing the pipes be careful not to pinch them firmly with pliers The pipes may get deformed Provide a protective shee...

Page 13: ...nect the compressor lead wires Remove the gasket Step Procedure Points Gasket R20126 Pattern 1 Pattern 2 C U white S V red R W blue C U white S V red R W blue Pattern 3 Pattern 4 C U white S W red R V blue C U white S W red R V blue R20298 R20989 R22652 R22653 ...

Page 14: ...the brazed part of the discharge side pipe and disconnect Heat up the brazed part of the suction side pipe and disconnect Remove the 3 nuts of the compressor Lift the compressor ASSY up and remove it Some models do not have the putty Step Procedure Points R22651 Brazed part Putty Nut ...

Page 15: ...16 RC35QRV161 RCA25 35QRV16 RCD25 35QRV16 RF35QRV16 RF35QRV161 RFA35QRV16 RFD35QRV16 RQ35QRV16 RQA35QRV16 RQD35QRV16 06 2016 Si011404EC Model addition RC35QRV1615 RC25RRV162 RC35RRV161 RC35RRV1615 RCA25RRV162 RCA35RRV161 RCD25RRV162 RCD35RRV161 RF35QRV1625 RF35RRV161 RF35RRV1615 RFA35RRV161 RFD35RRV161 RQ35QRV1625 RQ35RRV162 RQ35RRV1625 RQA35RRV162 RQD35RRV162 RUF35RRV161 ...

Page 16: ...sories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage electrical shock fire or explosion z Read the user s manual carefully before using this product The user s manual provides important safety instruc...

Reviews: