Removal of Electrical Components ASSY
Si01-879
8
Removal Procedure
2. Removal of Electrical Components ASSY
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the nut and
remove the terminal
cover.
Preparation
Remove the outer panels
and disconnect the
connector for the fan motor
according to the “Removal of
Outer Panels / Fan Motor”.
2
Disconnect the
compressor lead wires.
S(W) : Yellow
C(U) : Blue
R(V) : Red
3
Lift and remove the
electrical components
ASSY.
(R12790)
Terminal cover
(R12791)
Compressor lead wire
S(W)
C(U)
R(V)
(R6761)
(R12792)
Electrical Components ASSY