![Daikin R15LV14 Removal Procedure Download Page 4](http://html1.mh-extra.com/html/daikin/r15lv14/r15lv14_removal-procedure_4699550004.webp)
Outer Panels
Si011282EB
2
Removal Procedure
1. Outer Panels
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the 4 screws
and remove the top
panel.
Some models have only 1
screw on the left side of the
top panel.
2
3
Remove the 2 screws
of the discharge grille.
Unfasten the 6 hooks
and remove the
discharge grille.
4
5
Remove the 5 screws
of the front panel.
Unfasten the 4 hooks
and remove the front
panel.
Top panel
(R18562)
Hook
Hook
Hook
Front panel
Discharge grille
(R18563)
Hook
Hook
(R18564)