background image

Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global_ac/

All rights reserved

c

Warning

z

Daikin products are manufactured for export to numerous countries throughout the world. Prior to 
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this 
product conforms to the applicable standards, and is suitable for use, in the region where the product 
will be used. This statement does not purport to exclude, restrict or modify the application of any local 
legislation.

z

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. 
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

z

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or 
contractor to install those parts and accessories. Use of unauthorised parts and accessories or 
improper installation of parts and accessories can result in water or refrigerant leakage, electrical 
shock, fire or explosion.

z

Read the User's Manual carefully before using this product. The User's Manual provides important 
safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install     

the outdoor unit close to the sea shore, contact your local distributor.

Organization:
DAIKIN INDUSTRIES, LTD.
AIR CONDITIONING MANUFACTURING DIVISION

Scope of Registration:
THE DESIGN/DEVELOPMENT AND MANUFACTURE OF 
COMMERCIAL AIR CONDITIONING, HEATING, COOLING, 
REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, 
RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT 
RECLAIM VENTILATION, AIR CLEANING EQUIPMENT,  
COMPRESSORS AND VALVES.

Organization:
DAIKIN INDUSTRIES
(THAILAND) LTD.

Scope of Registration:
THE DESIGN/DEVELOPMENT
AND MANUFACTURE OF AIR 
CONDITIONERS AND THE 
COMPONENTS INCLUDING 
COMPRESSORS USED FOR THEM

All of the Daikin Group’s business 
facilities and subsidiaries in Japan 
are certified under the ISO 14001 
international standard for 
environment management.

JMI-0107

JQA-1452

Dealer

z

Specifications, designs and other content appearing in this brochure are current as of January 2013 but subject to change without notice.

Si241320

01/2013 AK

Summary of Contents for R13NUV2S

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Outdoor Unit Non Inverter Pair Type 1 5 HP Class Si241320...

Page 2: ...Service Manual Removal Procedure Outdoor Unit Applicable Models zCooling Only R13NUV2S...

Page 3: ...i241320 Removal Procedure 1 Table of Contents 1 Procedure to Remove Panels and Fan Motor 2 2 Procedure to Remove El Compo Box 8 3 Procedure to Remove Sound Blanket 9 4 Procedure to Remove Compressor 1...

Page 4: ...er supplies before disassembling work Step Procedure Points 1 Features Take care not to cut your finger by the fins of the heat exchanger The stop valve cover is united with the shelter When reassembl...

Page 5: ...he top panel 2 Disconnect the connector for fan motor The fan motor is united with the front panel 3 Loosen the 6 screws of the front panel 4 Undo the hooks Pull and remove the front panel The front p...

Page 6: ...screw the washer fitted nut M10 of the propeller fan with a spanner 2 Remove the propeller fan Align mark of the propeller fan with D cut section of the motor shaft when reassembling 3 Loosen the 2 sc...

Page 7: ...the fixing hooks and release the lead wire Put the lead wire through the back of the motor when reassembling so as not to be entangled with the propeller fan 5 Loosen the 4 screws to remove the fan mo...

Page 8: ...6 Removal Procedure 6 Loosen the 2 screws to remove the fan motor fixing frame 4 Remove the right side panel 1 Loosen the 2 screws on the rear side 2 Loosen the 4 screws on the right side Step Procedu...

Page 9: ...Si241320 Procedure to Remove Panels and Fan Motor Removal Procedure 7 3 Loosen the screw and lift the connection port to remove When reassembling make sure to fit the hook Step Procedure Points...

Page 10: ...inutes or more after turning off all power supplies before disassembling work Step Procedure Points Remove the top panel Disconnect the connector for fan motor 1 Remove the el compo box 1 Remove the t...

Page 11: ...turning off all power supplies before disassembling work Step Procedure Points Remove the outer panels Remove the el compo box 1 Remove the sound blanket 1 Untie the strings and open the sound blanke...

Page 12: ...ger fin Warning Since it may happen that refrigeration oil in the compressor will catch fire prepare wet cloth so as to extinguish fire immediately In case of the difficulty with gas brazing machine 1...

Page 13: ...Si241320 Procedure to Remove Compressor Removal Procedure 11 4 Lift the compressor up and remove it Step Procedure Points...

Page 14: ...Revision History Month Year Version Revised contents 01 2013 Si241320 First edition...

Page 15: ...duct The User s Manual provides important safety instructions and warnings Be sure to follow these instructions and warnings If you have any enquiries please contact your local importer distributor an...