4
|
Components
Service manual
182
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
Pins
Measured resistance (Ω)
2-3
706.8~813.2
2-4
2-5
3-4
3-5
4-5
Swing flap motor resistance
measurements are correct?
Action
Yes
Replace the swing flap motor wiring
harness, see
No
Replace the swing flap motor, see
182].
Repair procedures
To remove the swing flap motor
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
153].
1
Remove the switch box, see
2
Remove the swing flap from the indoor unit (by clicking it out).
3
Remove the 2 screws that fix the swing flap motor.
c
d
a
b
b
a
Swing flap
b
Screw (swing flap motor fixation)
c
Swing flap motor
d
Coupling piece
4
Remove the swing flap motor and coupling piece.
5
Remove the spring and remove the coupling piece from the swing flap motor.
6
Disconnect the wiring harness from the swing flap motor.
7