Removal Procedure
Humidifying Air Purifier
69
8. Removal of the pre-filter
1
Put your finger in the
recessed part of the
pre-filter upper section,
pull the filter toward
yourself and undo the
right and left hooks (4
in total).
★
When assembling the pre-
filter, put the 4 right and left
hooks of the pre-filter over
the 4 holes in the plasma-
ionizer unit and insert the
hooks into the holes.
2
When assembling, fit
the pre-filter to “front”
mark.
Step
Procedure
Points
(R9787)
(R9788)
Hooks
Hooks
Pre-filter
(R9789)
The upper left tab is
shaped differently
from the others.
Front mark