16
English
If you wish to turn Monitoring mode (within ECONO MODE) OFF
*Setting at time of purchase
Settings of Modes within ECONO MODE
Monitoring
ON*
Monitoring
OFF
Setting procedures
Remote controller
Unit
1.
Hold down
on the unit for about 5 seconds and when a short beep sounds, press
on the
remote controller while pressing
on the unit.
•
This setting change can be performed when the unit is on or off.
2.
Release both buttons when a short beep sounds.
•
The FAN lamp (Quiet) and ECONO MODE lamp will light up after blinking for about 5 seconds.
The ECONO MODE lamp will light up or blink depending on the ON/OFF status of Monitoring mode.
3.
Press
on the unit to change the setting.
•
Each press turns the ECONO MODE lamp ON or OFF.
(The FAN lamp (Quiet) will remain lit up.)
To turn Monitoring mode
ON
Turn on the ECONO MODE lamp.
To turn Monitoring mode
OFF
Turn off the ECONO MODE lamp.
Setting at time
of purchase
ON
OFF
•
Setting is indicated using the ECONO MODE lamp. If the ECONO MODE lamp does not change, unplug the unit, wait at
least 5 seconds, then reinsert the power supply plug and repeat the above procedure.
4.
Press
on the remote controller after making the new setting.
•
A short beep sounds and the FAN lamp (Quiet) will blink. When Monitoring mode is turned ON, the ECONO MODE
lamp also blinks.
Unplug the unit while the lamp is blinking, wait at least 5 seconds, and then reinsert the power supply plug.
Setting is now complete.
•
If this procedure is not performed, the unit will not return to regular operation mode.
Note
•
Settings are remembered even if the unit is unplugged.
Monitoring
ON*
Monitoring
OFF
Advanced Settings
01_EN_3P477288-1F.indd 16
9/28/2018 2:25:58 PM
Summary of Contents for MC55UVM6
Page 106: ......
Page 107: ......
Page 108: ...3P629501 4 2020 08 17 For manufacturing use only 3P629480 4 ...