IM 991-2 • MAVERICK II ROOFTOP 80 www.DaikinApplied.com
MicroTech III Controller Operation
Keypad/Display Menu Structure
The following is a description of the MicroTech III menu structure. These menus and items can all be displayed with the keypad/
display. Menu items displayed will change based on the selected unit configuration. Refer to
Figure 76:
Main Menu
– Keypad/Display Menu Structure
Main Menu
Enter Password
►
Quick Menu
►
View/Set Unit
►
Unit State=_________
Unit Status=________
MWU Status=
Dehum Status=
Ctrl Mode= Off
Occ Mode= Auto
HP Mode=
Commission Unit
►
Manual Control
►
Service Menus
►
Trending
►
Unit Maintenance
►
BMS Communications
►
Unit Configuration
►
Alarm Lists
►
About This Unit
►
Quick Menu
Unit State=__________
DAT Clg Spt= 55.0°F
Unit Status=_________
DAT Htg Spt= 85.0°F
MWU Status=_________
Min DAT Limit= 55.0°F
Dehum Status=________
Unocc Clg Spt= 85.0°F
Ctrl Mode= Off
Unocc Htg Spt= 55.0°F
Occ Mode= Auto/Net
SAF Speed= XXX%
HP Mode= Auto
Duct Press= X.Xin
Clg Capacity= XXX%
DuctSP Spt= 1.0in
OAD/Econ Cap= XXX%
RF/EF Cap= XXX%
Htg Capacity= XXX%
Bldg Press= X.XXin
Supl Htg Cap= XXX%
BldgSP Spt= 0.05in
Reheat Cap= XXX%
IAQ PPM= XXXXppm
Control Temp= XXX%
OA Flw= XXXXXCFM
Occ Clg Spt= 72.0°F
MinOAFlw Spt= 2000CFM
Occ Htg Spt= 68.0°F
OA Temp= XXX°F
Disch Air= XXX°F
EW Temp= XXX°F
Rel Humidity= XXX%
Manual Control
Manual Control= Normal
CFan Outpt 1= Off
Supply Fan= Off
CFan Outpt 2= Off
SAF Spd Cmd= 0%
CFan Outpt 3= Off
Manual Ctrl= Normal
BP/WR Valve= 0%
Supply Fan= Off
CW Valve= 0%
SAF Spd Cmd= 0%
ExhFan Out 1= Off
INV/OF Ena= Off
ExhFan Out 2= Off
INV Cmp= Off
ECond VFD= Off
INV Cmp Cmd= 0%
ECFan Spd Cmd= 0%
Comp 3= Off
EC Dm Valve= Close
OA Fan= Off
Sump Pump= Off
OA Fan Cmd= 0%
Sep Flsh Vlv= Off
4 Way Valve= Off
SV1= Off
RcvSol Valve=Off
SV2= Off
BP Sol Valve= Off
Gas Htg On/Off= Off
EVI Cmd= 0%
Htg Valve= 0%
EVO Cmd= 0%
SCR Out= 0%
RF/EF Fan= Off
F&BP Damper= 0%
RF/EF Spd Cmd= 0%
Htg Stg 1= Off
OAD/Econo= 0%
SCR Ena 1= Off
OAD OpCl= Close
Htg Stg 2= Off
Var Cmp= Off
SCR Ena 2= Off
Var Cmp Cmd= 0%
Htg Stg 3= Off
VCmp Emg Stop= Nrml
Htg Stg 4= Off
Comp 1= Off
Htg Stg 5= Off
Comp 2= Off
Htg Stg 6= Off
Comp 3= Off
Reheat Valve= 0%
Comp 4= Off
RH Output= Off
Comp 5= Off
LSCRH Valve= Off
Comp 6= Off
HGBP Valve= Off
Comp 7= Off
ERec Wheel= Off
Comp 8= Off
ER Whl Cmd= 0%
U1 Comp 1= Off
ERBP Dmpr Cl= Off
U1 Comp 2= Off
ERBP Dmpr Op= Off
U2 Comp 1= Off
Cond Wtr Pump= Off
U2 Comp 2= Off
Alm Output= Off
Cond Sol 1= Off
Fan Op Out= Off
Cond Sol 2= Off
About This Unit
SO_Item= 123456_12345
Unit SN= FBOU123456789
App Version= 2506017xxx
Cf1-15= xxxxxxxxxxxxxxxx
Cf6-29= xxxxxxxxxxxxxxxx
Main BSP= X.XX
LON BSP= X.XX
LON App Ver= X.XX
BACnet BSP= X.XX
D-Net BSP= X.XX
HMI GUID=
xxxxxxxx-xxxx-xxxx-xxxx-
xxxxxxxxxxxx
OBH GUID=
xxxxxxxx-xxxx-xxxx-xxxx-
xxxxxxxxxxxx
Unit Maintenance
Operating Hours
View/Set Unit
Unit Status/Settings
►
Occupancy
►
Temperatures
►
Flow Status
►
SAF Spd Control
►
RF/EF Control
►
Cooling
►
Economizer
►
Min OA Damper
►
Heating
►
Dehumidification
►
Date/Time/Schedules
►
Enter Password
Enter Password *******
►
BMS Communications
LON Set-Up
►
BACnet MSTP Set-Up
►
BACnet IP Set-Up
►
D-Net Set-Up
►
Network Unit Set-Up
►
Comm Slot 1= 0
Comm Slot 2= 0
Comm Slot 3= 0
Unit Configuration
Apply Changes= No
Unit Type= RTU(0)
Control Type= DAT(1)
Clg Type= Comp(1)
Comp Config= 424(1)
Gen Clg Stgs=/VFDCmpCFG= 8
Low Ambient= No(0)
Cond Ctrl= Std2(0)
OA Dmpr/Econ= AirEc(3)
OA Flow Stn= None(0)
Htg Type= None(0)
Htg Stages= 1
Max Heat Rise= 100
SAF Type= CAV(0)
RAF Type= CAV(0)
RF/EF Ctrl= Track(1)
2ndDSPSnsr= No(0)
EFT/LCT Snsr= No(0)
Energy Rcvy= None(0)
Clg Circ Type= 2Air(2)
Head P Ctrl= No(0)
Bypass Ctrl= Slave(0)
Unit Size= 050
Refrig Type= R410A(2)
Reheat Type= None(0)
Unit Voltage= 460/60(2)
EV Type= EVBSag
Apply Changes= No
Commission Unit
Unit Set-Up
►
Timer Settings
►
SAF Set-Up
►
RF/EF Set-Up
►
Htg/Clg ChgOvr Set-Up
►
Cooling Set-Up
►
INV Cmp Set-Up
►
Var Cmp Set-Up
►
Econo Set-Up
►
Min OA Set-Up
►
Heating Set-Up
►
OA Fan Set-Up
►
Exp Valve Set-Up
►
Defrost Set-Up
►
Dehum Set-Up
►
Energy Rec Set-Up
►
Head Pressure Set-Up
►
Evap Cond Set-Up
►
D3 Set-Up
►
Alarm Configuration
►
Service Menus
Timer Settings
►
Operating Hours
►
Save/Restore Settings
►
Active Alarms
►
Alarm Log
►
Alarm Configuration
►
Analog Input Status
►
Universal I/O Status
►
Digital Input Status
►
Digital Output Status
►
Network Input Status
►
Modbus Status
►
D3 Status
►
Sensor Offsets
►
Reset Counter= XXXX
Trending
Trending Ena= No
Apply Chgs= No
Sample Time= 300s
TrendOnOff= Off
Export Data= No
Clear Trend= Done
Points 1–8 (Fixed)
►
Points 9–24 (from List)
►
Points 25–27 (with IDs)
►
Points 28–30 (with IDs)
►
Alarm Lists
Active Alarms
►
Alarm Log
►