Daikin KRP067A41 Installation Manual Download Page 3

1P398933-1C

1. Remove the front panel and the front grille and service lid of 

indoor unit.

(Refer to the front page for the removal of each part in detail.)

2. Remove the electrical wiring box cover.

1.  Install the HA PCB (this set). (See Fig. 1)

1) Install the HA PCB (this set) to the electrical wiring box.

2) Insert the connector of the HA PCB (this set) to the connector (S403) on the electrical wiring box.

2.  Connect the HA connection cord. (See Fig. 1 and 2)

1) Insert the HA connection cord into the HA connector “S21” (white) on the HA PCB (this set).

2) Route the HA connection cord as shown in Fig. 2.

If there is workspace on the right-hand side of the indoor unit, the installation work can be 

conducted without removing the electrical wiring box.

Connect HA without removing the electrical wiring box, if possible.

Connecting HA PCB

Removal of Electrical Wiring Box Cover

Removal of Electrical Wiring Box

Fig. 1 Connection points of the HA PCB

Fig. 2 Routing HA connection cord

1. Disconnect the inter-unit wire.
2. Disconnect the fan motor connector (S200) and swing motor connector (S6). 
3. Disconnect the thermistor and ground/earth wire from the heat exchanger (2 screws).

(Some models may not have ground/earth wire.)

4. Remove the mounting screw of the electrical wiring box (1 screw).

HA PCB

HA connector “S21” (white)

Installing HA PCB on the electrical wiring box

Electrical wiring box

Back of the HA PCB

Spacer

S403

Insert the cord 

into the S403 

connector.

HA connector “S21” (white)

HA PCB

Electrical wiring box

Mounting screw of 

electrical wiring box

*The position of the ground/earth wire

  may differ depending on the model

Make sure that the mounting 

bracket of the thermistor will not 

fall off.

Thermistor

Inter-unit wire

Ground/Earth wire*

(Green/Yellow)

Ground/Earth wire*

(Green)

S200

S6

WARNING

 •  Be sure to turn OFF the power at the time of 

installation work.

Touching any electric parts with the power 
turned ON may cause electric shock.

Electrical wiring box cover

Disengage the hooks.

Electrical wiring box

If there is workspace on the right-hand side of the 
indoor unit, the installation work can be conducted 
without removing the electrical wiring box.

After connecting the HA PCB (this set), 
return all removed parts to their original 
positions.

After connecting the HA PCB (this set), 
return all removed parts to their original 
positions.

After connecting the HA PCB (this set), 
return all removed parts to their original 
positions.

1P398933-1C.indd   2

5/11/2016   12:05:18 PM

Summary of Contents for KRP067A41

Page 1: ...stallation Manual 1 1 Quantity Quantity Main component Installation Position Wiring Outline Do not install the air conditioner where gas leakage would be exposed to open flames If the gas leaks and builds up around the unit it may catch fire Touch a nearby metal object doorknob aluminium sash etc to discharge static electricity from your body before touching this set Static electricity from your bod...

Page 2: ...he front panel When there is no work space because the unit is close to ceiling Disengage the flap horizontal blade and pull the lower part of the front grille toward yourself to remove it If it is difficult to remove place both hands under the center of the front grille and while pushing up pull it toward yourself Removal method 1 Remove front panel 2 Remove the air filter 3 Remove the screws 2 from...

Page 3: ...h wire 4 Remove the mounting screw of the electrical wiring box 1 screw Mounting screw of electrical wiring box The position of the ground earth wire may differ depending on the model Make sure that the mounting bracket of the thermistor will not fall off Thermistor Inter unit wire Ground Earth wire Green Yellow Ground Earth wire Green S200 S6 WARNING Be sure to turn OFF the power at the time of i...

Page 4: ...e HA connector S21 white on the HA PCB this set 2 Route the HA connection cord as shown in Fig 2 Connecting HA PCB Fig 1 Connection points of the HA PCB Fig 2 Routing HA connection cord HA PCB HA connector S21 white Installing HA PCB on the electrical wiring box Electrical wiring box Back of the HA PCB Spacer S403 Insert the cord into the S403 connector HA connector S21 white HA PCB Electrical wir...