 CLEANING BEFORE AND AFTER SEASONAL USE

WHAT TO DO WHEN STARTING UP AFTER A LONG 

PERIOD OF NO USE

Confirm the following.

• 

Check that the air inlet and outlet of indoor and outdoor unit 
are not blocked. 
Remove any obstacle. 
Obstacles decrease the fan speed, and cause performance 
decrease and may damage the unit.

Clean the air filter.

• 

After cleaning the air filter, make sure to reinstall it. 
(Refer to “

2. MAINTENANCE” on page 1.) 

For information on how to install, remove, or clean the 
optional air filter, refer to the installation manual attached to 
the air filter.

• 

Turn off the indication “Time to clean filter” displayed on the 
remote controller after turning on the power.

• 

For details, refer to the operation manual attached to the 
remote controller. 
The indication can be turned off whether in operation or at 
stop. 

Turn on the power circuit breaker at least 6 hours before 

operation.

• 

This is required in order to activate the air conditioner 
smoothly, and to protect the air conditioner.

• 

The display on the remote controller will be shown when 
the power circuit breaker is turned on.

HEATING OPERATION within 6 hours after power is 

supplied to the air conditioner.

Some model series perform the following operation to protect 
the equipment.
If the HEATING OPERATION is performed within 6 hours after 
power is supplied to the air conditioner, the indoor fan stops for 
about 10 minutes during the outdoor unit operation to protect 
the equipment.
The above operation is performed not only for installation, but 
every time the power circuit breaker is turned off/on.
For comfortable use, do not turn off the power circuit breaker 
during seasonal use of the HEATING OPERATION.

WHAT TO DO WHEN STOPPING THE AIR 

CONDITIONER FOR A LONG PERIOD

Turn on FAN OPERATION for a half day on a nice day and 

dry the indoor unit.

• 

This can prevent the causes of mold.

Turn off the power circuit breaker.

• 

When the power circuit breaker is on, some electricity is 
used even if the air conditioner is not operating. 
Turn off the power circuit breaker to save energy.

• 

When the power circuit breaker is off, there is no longer a 
display on the remote controller. 

Clean the air filter.

• 

Be sure to reinstall the air filter after cleaning. 
(Refer to “

2. MAINTENANCE” on page 1.) 

For information on how to install, remove, or clean the 
optional air filter, refer to the installation manual attached to 
the air filter.

NOTE 
The inside of the air conditioner may become dusty after 
several seasons of use, potentially causing performance 
degradation and water leakage.
Ask your local dealer for details on cleaning the inside of the 
indoor unit. This operation requires a qualified service person.

01_EN_3P494229-1.indd   4

8/9/2017   14:22:35

Summary of Contents for FXZQ05TAVJU

Page 1: ...SYSTEM Inverter Air Conditioners OPERATION MANUAL MODELS Ceiling Mounted Cassette type Multi Flow FXZQ05TAVJU FXZQ07TAVJU FXZQ09TAVJU FXZQ12TAVJU FXZQ15TAVJU FXZQ18TAVJU English Français Español ...

Page 2: ...eur Il vous expliquera comment vous servir correctement de l appareil et vous guidera en cas de problème Ce manuel ne décrit que l unité intérieure Utilisez le avec le manuel de l unité extérieure Lorspue vous aurez lu le manuel rangez le afin de pouvoir vous y référer ultérieurement Le agradecemos la compra de este acondicionador de aire Daikin Lea cuidadosamente el manual de funcionamiento antes...

Page 3: ...Contact your dealer for repair and maintenance Im proper repair and maintenance may result in water leakage electric shock and fire Only use accessories made by Daikin that are specifically designed for use with the equipment and have them installed by a pro fessional Contact your dealer to move and reinstall the air condi tioner or heat pump Incomplete installation may result in water leakage ele...

Page 4: ... to malfunction Do not place appliances that produce open flames in places that are exposed to the airflow of the unit or un der the indoor unit It may cause incomplete combus tion or deformation of the unit due to the heat Do not expose the controller to direct sunlight The LCD display can become discolored and may fail to display the data Do not wipe the controller operation panel with ben zene ...

Page 5: ...t wipe the air conditioner with benzine or thinner It may cause cracks electric shocks or a fire Never put your fingers or rods in the air inlet air outlet or horizontal blade The fan is rotating at high speed so you would get injured CAUTION Do not wash the air conditioner with water It may cause electric shocks or a fire due to leakage Make sure to turn off the air conditioner when taking care o...

Page 6: ...ng a soft brush After dewatering dry the air filter in the shade NOTE Do not wash the air filter with hot water of 122 F 50 C or higher It may cause decolorization and deformation When drying the filter do not heat it with fire It may cause burning Do not use chemicals such as gasoline benzine thin ner polishing powder and liquid insecticide sold in the market It may cause discoloration and deform...

Page 7: ...with fire It may cause burning Do not use chemicals such as gasoline benzine thin ner polishing powder and liquid insecticide sold in the market It may cause discoloration and deformation 5 Attach the air filter Refer to step 4 of HOWTO CLEANTHE AIR FILTER page 2 6 Attach the suction grille Position the suction grille to a roughly 90 angle and while holding the suction grille with one hand squeeze...

Page 8: ...tect the equipment If the HEATING OPERATION is performed within 6 hours after power is supplied to the air conditioner the indoor fan stops for about 10 minutes during the outdoor unit operation to protect the equipment The above operation is performed not only for installation but every time the power circuit breaker is turned off on For comfortable use do not turn off the power circuit breaker d...

Page 9: ... 1709 HT 3P494229 1 EM17A017 ...

Reviews: