Daikin FXSQ-P Technical Data Manual Download Page 10

• Indoor Unit • Round Flow Cassette • FXSQ-P

• VRV® Systems • Indoor Unit

8

4

Options

F

X

SQ20-140P

3TW31189-3D

Options

Oper

a

tion Control

(*1): Electrical heater and humidifier are field su

pp

ly. These 

p

arts should not be installed inside the e

q

ui

p

ment (refer to installation manual EKR

P

1B

2

A)

(*

2

): If installing an electrical heater, an o

p

tion 

PC

B for external heater (EKR

P

1B

2

) for each indoor unit is re

q

uired.

(*3): An electrical heater can not be used for 

V

R

V

 system cooling only.

(*4): Mounting 

p

late KR

P

4A

9

6 is re

q

uired for these o

p

tions. Maximum 

2

 o

p

tion 

PC

B’s can be mounted.

(*5): Decoration 

p

anel o

p

tion EKBYBSD is re

q

uired for direct mounting of the decoration 

p

anel on the unit.

Contents of 

a

ccessory b

a

g

Item

Ty

p

e

FXSQ

2

0,

2

5,3

2

FXSQ40,50

FXSQ63,80

FXSQ100,1

2

5,140

P

anel related

Decoration 

p

anel (*5)

BYBS3

2

BYBS45D

BYBS71D

BYBS1

2

5D

Air inlet and air discharge outlet related

Air discharge ada

p

ter for round duct

KDAJ

2

5K36A

KDAJ

2

5K56A

KDAJ

2

5KA71A

KDAJ

2

5KA140A

P

anel related

Decoration 

p

anel o

p

tion

EKBYBSD

Item

Ty

p

e

FXSQ

2

0,

2

5,3

2

FXSQ40,50

FXSQ63,80

FXSQ100,1

2

5,140

Remote 

C

ontrol

W

ired Ty

p

e

BR

C

1D5

2

8 / BR

C

1E51A

Infrared ty

p

e

H

P

BR

C

4

C

65

C

O

BR

C

4

C

66

Sim

p

lified remote control

BR

C2C

51

Remote control for hotel use

BR

C

3A61

O

p

tion B

C

B for external el. heater, humidifier and/or hour meter (*1), (*

2

), (*3), (*4)

EKR

P

1B

2

A

Ada

p

ter for wiring (interlock for fresh air intake fan) (*4) 

KR

P

1

C

64

W

iring ada

p

ter for electrical a

pp

endices (1) (*

2

), (*4)

KR

P2

A51

W

iring ada

p

ter for electrical a

pp

endices (

2

) (*4)

KR

P

4A51

Remote sensor

KR

C

S01-4B

C

entral remote control

D

C

S30

2C

A51

Electrical box with earth terminal (3 blocks)

KJB311A

Unified ON/OFF control

D

C

S301BA51

Electrical box with earth terminal (

2

 blocks)

KJB

2

1

2

A

Schedule timer

DST301BA51

External ada

p

ter for outdoor unit (installation on indoor unit) (*4)

DTA104A61

Mounting 

p

late for ada

p

ter 

PC

B

KR

P

4A

9

6

Descri

p

tion

Quantity

FXSQ 

2

0,

2

5,3

2

,40,50,63,80,100,1

2

5,140

Hexagon ta

pp

ing screw (M5x16)

16

Round 

p

lain washer for wood

8

Installation and o

p

eration manual

1

Hose band

1

Insulation for joint (

G

AS)

1

Insulation for joint (LIQUID)

1

Drain hose

1

Drain hose sealing material

1

Sealing material

2

NOTES

FXSQ_EN.pdf   10

29/06/2010   14:31:34

Summary of Contents for FXSQ-P

Page 1: ...FXSQ P E E D E N 1 0 2 0 0 Air Conditioners Round Flow Cassette Technical Data...

Page 2: ...FXSQ P E E D E N 1 0 2 0 0 Air Conditioners Round Flow Cassette Technical Data...

Page 3: ...ions 8 5 Capacity tables 9 Cooling Capacity Tables 9 Heating Capacity Tables 11 6 Dimensional drawings 13 7 Centre of gravity 15 8 Piping diagrams 16 9 Wiring diagrams 17 Wiring Diagrams Single Phase...

Page 4: ...coration panel Model BYBS32DJW1 BYBS45DJW1 Colour White 10Y9 0 5 Dimensions Height mm 55 0d Width mm 650 800 Depth mm 500 Weight kg 3 0 3 5 Required ceiling void mm 350 Heat exchanger Fin pitch mm 1 7...

Page 5: ...acity Nom kW 8 0 2 10 0 2 12 5 2 16 0 2 18 0 2 Power input 50Hz Cooling Nom kW 0 074 1 0 118 1 0 117 1 0 185 1 0 261 1 Heating Nom kW 0 062 2 0 106 2 0 105 2 0 173 2 0 249 2 Power input 60Hz Cooling N...

Page 6: ...rpm 975 1161 1060 1218 1325 Low rpm 840 960 813 920 948 Heating High rpm 975 1161 1060 1218 1325 Low rpm 840 960 813 920 948 Output High W 350 Drive Direct drive Sound pressure level Cooling High dBA...

Page 7: ...al overcurrent amps TOCA A Maximum fuse amps MFA A 16 Current 60Hz Minimum circuit amps MCA A 0 5 1 2 Maximum fuse amps MFA A 16 1 2 Electrical Specifications FXSQ63P7VEB FXSQ80P7VEB FXSQ100P7VEB FXSQ...

Page 8: ...16 FXSQ50 1 2 16 FXSQ63 1 1 16 FXSQ80 1 3 16 FXSQ100 1 6 16 FXSQ125 2 1 16 FXSQ140 3 1 16 SYMBOLS NOTES MCA Min Circuit Amps A 1 Voltage range Units are suitable for use on electrical systems where vo...

Page 9: ...80 100 125 140 FXSQ PC Board Fuse 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A PC Board Fuse Fan Driver 250V 5A 250V 5A 250V 5A 250V 5...

Page 10: ...related Decoration panel option EKBYBSD Item Type FXSQ20 25 32 FXSQ40 50 FXSQ63 80 FXSQ100 125 140 Remote Control Wired Type BRC1D528 BRC1E51A Infrared type HP BRC4C65 CO BRC4C66 Simplified remote con...

Page 11: ...2 9 2 5 3 4 2 8 3 6 2 9 3 8 2 9 4 3 3 0 4 4 3 0 18 0 2 4 2 2 2 9 2 5 3 4 2 8 3 6 2 9 3 8 2 9 4 2 3 0 4 3 2 9 20 0 2 4 2 2 2 9 2 5 3 4 2 8 3 6 2 9 3 8 2 9 4 2 2 9 4 3 2 9 21 0 2 4 2 2 2 9 2 5 3 4 2 8...

Page 12: ...21 0 7 6 6 4 9 0 7 3 10 5 8 3 11 2 8 5 11 9 8 7 12 9 8 8 13 2 8 5 23 0 7 6 6 4 9 0 7 3 10 5 8 3 11 2 8 5 11 9 8 7 12 7 8 7 13 0 8 4 25 0 7 6 6 4 9 0 7 3 10 5 8 3 11 2 8 5 11 9 8 7 12 5 8 6 12 8 8 3 27...

Page 13: ...2 6 2 6 2 5 14 7 15 0 2 7 2 7 2 7 2 7 2 7 2 7 12 6 13 0 2 9 2 9 2 8 2 8 2 8 2 8 10 5 11 0 3 0 3 0 3 0 3 0 3 0 3 0 9 5 10 0 3 1 3 1 3 1 3 1 3 0 3 0 8 5 9 1 3 1 3 1 3 1 3 1 3 1 3 1 7 0 7 6 3 2 3 2 3 2 3...

Page 14: ...5 9 5 9 5 9 5 8 5 9 1 9 8 9 8 9 7 9 7 9 7 9 7 7 0 7 6 10 1 10 1 10 1 10 1 10 1 10 0 5 0 5 6 10 6 10 5 10 5 10 5 10 5 10 5 3 0 3 7 11 0 11 0 10 9 10 9 10 9 10 9 0 0 0 7 11 6 11 6 11 6 11 6 11 6 10 9 3...

Page 15: ...side 10 Nameplate View A A Detail B Suspension bolt Service space Detail B 350 or more Service space Suspension position Suspension position FXSQ40 50P 3TW31214 1A NOTE 1 Refer to outlook drawing for...

Page 16: ...10 Nameplate View A A Detail B Suspension bolt Service space Detail B 350 or more Service space Suspension position Suspension position or more FXSQ100 140P 3TW31254 1A NOTE 1 Refer to outlook drawing...

Page 17: ...3 VRV Systems Indoor Unit 15 Indoor Unit Round Flow Cassette FXSQ P 7 Centre of gravity FXSQ P 4TW31189 1B Model A B FXSQ20 32 220 550 FXSQ40 50 283 700 FXSQ63 80 441 1000 FXSQ100 125 140 619 1400...

Page 18: ...SQ20 140P 3TW31185 1A Heat exchanger Liquid pipe connection port Gas pipe connection port Filter Filter Electronic expansion valve Refrigerant flow Cooling Heating Refrigerant pipe connection port dia...

Page 19: ...GLRGH 6HUYLFH PRQLWRU JUHHQ 1RLVH OWHU HUULWH FRUH 35 5 0DJQHWLF UHOD 1RLVH OWHU 5 5HDFWRU RQQHFWRU RSWLRQDO DFFHVVRU 0 0RWRU IDQ RQQHFWRU 3RZHU VXSSO IRU ZLULQJ 0 3 0RWRU UDLQ SXPS RQQHFWRU RU ZLULQJ...

Page 20: ...dB 20 Pa 5 Location of microphine Sound pressure level dB Octave band center frequency dB 1 5m Microphone Unit 2m 2m 1 5m 1m High tap Medium tap Low tap Discharge Suction FXSQ40 50P 3TW31217 2 Notes 1...

Page 21: ...ic pressures 0dB 20 Pa 5 Location of microphine Sound pressure level dB Octave band center frequency dB 1 5m Microphone Unit 2m 2m 1 5m 1m High tap Medium tap Low tap Discharge Suction FXSQ125P 3TW312...

Page 22: ...3 Measured according to ISO 3744 Sound pressure level dB Octave band center frequency dB High tap Medium tap Low tap FXSQ40 50P 3TW31217 1 Notes 1 dBA A weighted sound power level A scale according t...

Page 23: ...le according to IEC 2 Reference acoustic intensity 0dB 10E 6 W m2 3 Measured according to ISO 3744 Sound pressure level dB Octave band center frequency dB High tap Medium tap Low tap FXSQ125P 3TW31267...

Page 24: ...ent Lower limit of ESP by airflow auto adjustment Lower limit of ESP External static pressure Pa External static pressure Pa H M L External static pressure Pa FXSQ32P 3TW31208 1 Fan characteristics 1...

Page 25: ...ent Lower limit of ESP by airflow auto adjustment Lower limit of ESP External static pressure Pa External static pressure Pa External static pressure Pa H M L FXSQ63P 3TW31238 1 Fan characteristics 1...

Page 26: ...ent Lower limit of ESP by airflowautoadjustment Lower limit of ESP External static pressure Pa External static pressure Pa H M L External static pressure Pa FXSQ100P 3TW31258 1 Fan characteristics 1 F...

Page 27: ...P by airflow auto adjustment Lower limit of ESP External static pressure Pa External static pressure Pa External static pressure Pa H M L 64 3 7 127 6 DQ FKDUDFWHULVWLFV DV VKRZQ DUH LQ IDQ RQO PRGH 6...

Page 28: ...ng return Installation with duct Direct installation of inlet panel EKBYBSD is required for direct installation Wide variety of installation methods Easy modification from rear to bottom suction Drain...

Page 29: ...n with air inlet duct or less NOTES Nr Description 1 When installing the unit with rear suction a service opening is necessary for the maintenance of the air filters 2 When installing the unit with a...

Page 30: ...Indoor Unit Round Flow Cassette FXSQ P VRV Systems Indoor Unit 28 12 Installation 12 3 Switch Box Connection FXSQ20 140P 3TW31184 5A...

Page 31: ...his challenge demands the eco design and development of a wide range of products and an energy management system resulting in energy conservation and a reduction of waste VRV products are not within t...

Reviews: