background image

3

5

•  VRV Systems • FXLQ-P  

7

•  Indoor Unit • FXLQ-P  

5

Options

5 - 1

Options

FXLQ-P

BRP7A51③④

EKMTAC

EKRDP63A9

EKRDP40A9

EKRDP25A9

KAFJ361K71

KAFJ361K45

KAFJ361K28

DTA104A61

DST301BA51

KEK26-1

DCS301BA51

KJB311A

KJB212A

DCS302B51

KRCS01-1

KRP4A51

KRP2A51

KRP1B61

BRC3A61

BRC3E52C②⑧

BRC2E52C②⑧

BRC4C66

BRC4C65

BRC1D52/BRC1E53A7⑤

BRC1E53B7⑥/BRC1E53C7⑦⑧

FXLQ25P2VEB

FXLQ40P2VEB

FXLQ63P2VEB

FXNQ25P2VEB

FXNQ40P2VEB

FXNQ63P2VEB

FXLQ20P2VEB

FXLQ32P2VEB

FXLQ50P2VEB

FXNQ20P2VEB

FXNQ32P2VEB

FXNQ50P2VEB

Option kit

Product name

Availability

Included languages are:

Language pack 1: English, German, French, Dutch, Spanish, Italian, and Portuguese.

Language pack 2: English, Bulgarian, Croatian, Czech, Hungarian, Romanian, and Slovenian.
Language pack 3: English, Greek, Polish, Russian, Serbian, Slovak, and Turkish.

With PC cable EKPCCAB3 in combination with the Updater PC software, you can additionally change the language to:

Only possible in combination with remote control BRC2/3E52C, BRC1E53A/B/C7.
Requires installation box for adaptor PCB
Included languages are: English, German, French, Italian, Spanish, Portuguese, and Dutch.
Included languages are: English, Czech, Croatian, Hungarian, Slovenian, Romanian, and Bulgarian.
Included languages are: English, Russian, Greek, Turkish, Polish, Albanian, and Slovak.
Language pack 3 of controller BRC1E53C7 is different from that of controller BRC2/3E52C7.

Rear decoration panel

Simplified remote control (with operation mode selector button)
Simplified remote control (without operation mode selector button)

Wiring adaptor for electrical appendices 1
Wiring adaptor for electrical appendices 2

Multi-tenant

Remote sensor

Long-life replacement filter

Central remote control

Unified ON/OFF controller

Electrical box with earth terminal (2 blocks)
Electrical box with earth terminal (3 blocks)

Schedule timer

Digital input adaptor

Wired remote control

Wireless remote control HP
Wireless remote control CO

Remote control for hotel use
Adaptor for wiring

Noise filter (for electromagnetic interface only)

External adaptor for outdoor unit (installation on indoor unit)

Long-life replacement filter
Long-life replacement filter

Rear decoration panel
Rear decoration panel

This kit contains parts to connect with 10 multi-tenant indoor units.

4D082403

 3D102604

Summary of Contents for FXLQ-P Series

Page 1: ...Air Conditioning Technical Data FXLQ P FXLQ20P2VEB FXLQ25P2VEB FXLQ32P2VEB FXLQ40P2VEB FXLQ50P2VEB FXLQ63P2VEB...

Page 2: ......

Page 3: ...lectrical Specifications 3 3 Electrical data 5 4 Safety device settings 6 5 Options 7 6 Capacity tables 8 Cooling Capacity Tables 8 Heating Capacity Tables 9 7 Dimensional drawings 10 8 Centre of grav...

Page 4: ...casing finished in pure white RAL9010 and iron grey RAL7011 blends easily with any interior Requires very little installation space Wall mounted installation facilitates cleaning beneath the unit whe...

Page 5: ...282 Stages Quantity 14 Fin Type Cross fin coil Fan Type Sirocco fan Air flow rate 50Hz Cooling High m min 7 8 11 14 16 Low m min 6 0 8 5 11 0 12 0 Fan motor Drive Direct drive Air filter Type Resin ne...

Page 6: ...n electrical systems where voltage supplied to unit terminal is not below or above listed range limits Maximum allowable voltage range variation between phases is 2 MCA MFA MCA 1 25 x FLA MFA 4 x FLA...

Page 7: ...RU DERYH OLVWHG UDQJH OLPLWV 0D LPXP DOORZDEOH YROWDJH XQEDODQFH EHWZHHQ SKDVHV LV 0 0 0 0 QH W ORZHU VWDQGDUG IXVH UDWLQJ 0LQ 6HOHFW ZLUH VL H EDVHG RQ WKH 0 QVWHDG RI IXVH XVH LUFXLW UHDNHU 4 3 8QL...

Page 8: ...Indoor Unit FXLQ P 4 VRV Systems FXLQ P 6 4 Safety device settings 4 1 Safety Device Settings...

Page 9: ...are English German French Italian Spanish Portuguese and Dutch Included languages are English Czech Croatian Hungarian Slovenian Romanian and Bulgarian Included languages are English Russian Greek Tu...

Page 10: ...TC SHC TC SHC TC SHC TC SHC TC SHC 20 1 5 1 3 1 8 1 5 2 1 1 7 2 2 1 7 2 3 1 7 2 4 1 6 2 4 1 5 25 1 9 1 6 2 3 1 8 2 6 2 0 2 8 2 1 3 0 2 1 3 0 2 0 3 1 1 9 32 2 4 2 1 2 9 2 2 3 4 2 5 3 6 2 5 3 8 2 5 3 9...

Page 11: ...Capacity Tables Unit size Indoor air temp CDB 16 0 18 0 20 0 21 0 22 0 24 0 kW kW kW kW kW kW 20 2 6 2 6 2 5 2 4 2 3 2 2 25 3 4 3 4 3 2 3 1 3 0 2 8 32 4 2 4 2 4 0 3 9 3 7 3 5 40 5 2 5 2 5 0 4 8 4 7 4...

Page 12: ...XVWLQJ VFUHZ LQ VWDQGDUG DFFHVVRU 0 2EORQJ KROH ROH IRU I LQJ WR WKH I RRU 2EORQJ KROH ROH IRU IHDU PRXQWLQJ LULQJ KROH ERWWRP 3LSLQJ KROH ERWWRP 7 RU PRUH 4 3 WHP 1DPH HVFULSWLRQ LTXLG SLSH FRQQHFWLR...

Page 13: ...QHFWLRQ DV SLSH FRQQHFWLRQ ODUH FRQQHFWLRQ UDLQ SLSH FRQQHFWLRQ 2 6ZLWFK ER LU I OWHU RU PRUH RU PRUH URQW RI IDFH RU PRUH LVFKDUJH 6XFWLRQ RU PRUH DVH 5HTXLUHG LQVWDOODWLRQ VSDFH 3LSLQJ KROH UHDU HYH...

Page 14: ...Indoor Unit FXLQ P 8 VRV Systems FXLQ P 12 8 Centre of gravity 8 1 Centre of Gravity 7 4 3 0RGHO 4 3 4 3 4 3...

Page 15: ...sion valve Filter Filter Gas pipe connection port Liquid pipe connection port Fan 4D034245R Applicable model FXC FXM FXL FXN FXH FXK FXS FJSP CBXLS FXSP FXCP FZSP FXNP FJNP FHQ FXA FXMQ FBQ FXAQ FXSP...

Page 16: ...l block control Y1E Electronic expansion valve Wired remote control R1T Thermistor air SS1 Select switch main sub Connector optional accessory X18A Connector wiring adapter for electrical appendices 2...

Page 17: ...equency Hz Octave band sound pressure level dB 0 dB 0 0002 bar Scale 220V 240V H L H L A 35 32 37 34 C 39 37 41 39 220V 240V 1 5m 1 5m Microphone NOTES 1 Over all dB B G N is already rectified 2 Measu...

Page 18: ...nditons Power source 220 240V 220V 50 60Hz JIS standard 4 Location of microphone 5 Operating noise differs with operation and ambient conditions FXLQ63P 4D034567A Approximate threshold hearing for con...

Page 19: ...this leaflet to the best of its knowledge No express or implied warranty is given for the completeness accuracy reliability or fit ness for particular purpose of its content and the products and serv...