background image

2e

ÈEEDEN08-204aËÍ

Daikin Europe N.V. is approved by LRQA for its
Quality Management System in accordance with the
ISO9001 standard. ISO9001 pertains to quality
assurance regarding design, development,
manufacturing as well as to services related to the
product. 

Daikin units comply with the European 
regulations that guarantee the safety of 
the product.

E

E

D

EN

08

-2

04

  •

 0

1/

2

00

8 •

 Co

py

righ

t ©

 Dai

kin

Th

e pr

ese

n

p

u

b

lic

at

ion

 su

per

sed

es EE

DE

N07-200

Pr

ep

ar

ed 

in

 B

e

lgi

u

by

 La

n

n

o

o

  (

www

.la

n

no

op

ri

nt

.b

e),

 a

 c

o

mp

an

y w

h

ose

 co

n

cer

fo

the envir

o

nmont is 

set

 in the 

E

M

A

S a

n

d

 ISO 14001 syste

ms.

Re

spo

n

sib

le E

d

ito

r:

 Da

ik

in 

E

u

ro

pe N.

V.

, Za

ndvo

or

des

tra

at

 300,

 B- 8400 Oos

tende

The present publication is drawn up by way of information only and
does not constitute an offer binding upon Daikin Europe N.V.. Daikin
Europe N.V. has compiled the content of this publication to the best
of its knowledge. No express or implied warranty is given for the
completeness, accuracy, reliability or fitness for particular purpose of
its content and the products and services presented therein.
Specifications are subject to change without prior notice. Daikin
Europe N.V. explicitly rejects any liability for any direct or indirect
damage, In the broadest sense, arising from or related to the use
and/or interpretation of this publication. All content is copyrighted
by Daikin Europe N.V..

VRV

®

products are not within the scope of the

Eurovent certification programme.

Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende

Daikin’s unique position as a manufacturer of air
conditioning equipment, compressors and
refrigerants has led to its close involvement in
environmental issues. For several years Daikin
has had the intension to become a leader in the
provision of products that have limited impact
on the environment. This challenge demands
the eco design and development of a wide
range of products and an energy management
system, resulting in energy conservation and a
reduction of waste.

ISO14001 assures an effective environmental
management system in order to help protect human
health and the environment from the potential
impact of our activities, products and services and to
assist in maintaining and improving the quality of the
environment.

Summary of Contents for FXFQ-P7VEB

Page 1: ...technical data RoundFlow Ceiling Mounted Cassette FXFQ P7VEB air conditioning systems EEDEN08 204 2e...

Page 2: ...ecifications 5 2 Safety device settings 6 3 Options 7 4 Capacity tables 8 Cooling capacity tables 8 Heating capacity tables 10 5 Dimensional drawing centre of gravity 12 Dimensional drawing 12 Centre...

Page 3: ...6 6 8 Empty Tubeplate Hole 4 4 Fin Fin type Cross fin coil Multi louver fins and Hi XSS tubes Fan Type Turbo fan Quantity 1 1 1 1 1 Air Flow Rate Cooling High m min 12 5 12 5 12 5 13 5 15 5 Low m min...

Page 4: ...16 0 Power Input Cooling kW 0 095 0 120 0 173 0 258 Heating kW 0 114 0 108 0 176 0 246 Casing Material Galvanised steel Dimensions Packing Height mm 220 262 262 304 Width mm 882 882 882 882 Depth mm...

Page 5: ...d operation manual Drain hose Washer for hanging bracket Screws Sealing Pads Insulation for fitting Clamp for drain hose Installation guide Drain sealing pad Notes The sound pressure values are mentio...

Page 6: ...2 MCA MFA MCA 1 25 x FLA MFA 4 x FLA next lower standard fuse rating minimum 16A select wire size based on the MCA instead of a fuse use a circuit breaker 1 2 ELECTRICAL SPECIFICATIONS FXFQ63P7VEB FXF...

Page 7: ...Q125P PC board fuse 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A Fan motor thermal fuse C Fan motor thermal protector C OFF 108 5 ON 96 15 OFF 108 5 ON 96 15 OFF 108 5 ON 96...

Page 8: ...ary for these adapters 2 All options are supplied as kit OPTIONS No Item Model FXFQ20P FXFQ25P FXFQ32P FXFQ40P FXFQ50P FXFQ63P FXFQ80P FXFQ100P FXFQ125P 1 Decoration panel BYCQ140CW1 2 Long life repla...

Page 9: ...1 9 1 7 2 3 1 9 2 6 2 0 2 8 2 1 3 0 2 2 3 1 2 1 3 2 2 1 33 0 1 9 1 7 2 3 1 9 2 6 2 0 2 8 2 1 3 0 2 2 3 1 2 1 3 1 2 0 35 0 1 9 1 7 2 3 1 9 2 6 2 0 2 8 2 1 3 0 2 2 3 0 2 1 3 1 2 0 37 0 1 9 1 7 2 3 1 9 2...

Page 10: ...10 8 6 9 11 2 6 7 20 0 6 1 5 2 7 2 5 8 8 4 6 4 9 0 6 5 9 6 6 7 10 8 6 9 11 1 6 6 21 0 6 1 5 2 7 2 5 8 8 4 6 4 9 0 6 5 9 6 6 7 10 8 6 9 11 0 6 6 23 0 6 1 5 2 7 2 5 8 8 4 6 4 9 0 6 5 9 6 6 7 10 6 6 8 1...

Page 11: ...0 2 2 3 1 3 1 3 1 3 1 3 0 2 8 5 0 4 1 3 3 3 2 3 2 3 1 3 0 2 8 7 0 6 0 3 4 3 4 3 2 3 1 3 0 2 8 9 0 7 9 3 5 3 4 3 2 3 1 3 0 2 8 11 0 9 8 3 6 3 4 3 2 3 1 3 0 2 8 13 0 11 8 3 6 3 4 3 2 3 1 3 0 2 6 15 0 1...

Page 12: ...11 0 7 5 7 5 7 5 7 5 7 4 7 4 9 5 10 0 7 7 7 7 7 6 7 6 7 6 7 6 8 5 9 1 7 8 7 8 7 8 7 8 7 8 7 8 7 0 7 6 8 1 8 1 8 1 8 1 8 0 8 0 5 0 5 6 8 4 8 4 8 4 8 4 8 4 8 4 3 0 3 7 8 8 8 8 8 7 8 7 8 7 8 7 0 0 0 7 9...

Page 13: ...RH 80 in the ceiling or fresh air is inducted into the ceiling an additional insulation is required polyethylene foam thickness 10mm or more 6 Please respect the distances as shown on the figure FXFQ8...

Page 14: ...an additional insulation is required polyethylene foam thickness 10mm or more 6 Please respect the distances as shown on the figure Nr Name Description 1 Liquid pipe connection 9 52 flare connection 2...

Page 15: ...be Field supply Air flow rate m3 min Ventilation resistance in chamber Note 6 Static pressure of chamber Pa Connecting chamber mounting space 455 Ceiling opening space FXFQ125P 3D057032 Nr Name Descri...

Page 16: ...nits 15 Indoor Units ROUNDFLOW CASSETTE FXFQ P7VEB 5 Dimensional drawing centre of gravity 5 2 Centre of gravity FXFQ P 4TW28839 2 Models A B C D FXFQ20 63 202 60 409 358 FXFQ80 100 246 90 411 411 FXF...

Page 17: ...ram FXFQ P 3TW28835 1 Heat exchanger Fan Filter Filter Electronic expansion valve Liquid pipe connection port Gas pipe connection port Refrigerant flow Cooling Heating Refrigerant pipe connection port...

Page 18: ...t switch SS1 Selector switch main sub F1U Fuse T 5A 250V X1M Terminal strip SS2 Selector switch wireless address set HAP Light emitting diode service monitor green X2M Terminal strip Connector for opt...

Page 19: ...Hz Low Hi Scale Mode Hi Low A 31 0 28 0 C 37 0 34 0 Drain up Mic position 1 5m 0 3m Hi 49 Note Operation noise differs with operation and ambient conditions 4D056869 NOTES Over All dB B G N is already...

Page 20: ...29 0 30 0 C 40 0 42 0 35 0 36 0 Hi Cooling Heating 52 54 Drain up Mic position 1 5m 0 3m Note Operation noise differs with operation and ambient conditions 4D056873 NOTES Over All dB B G N is already...

Page 21: ...e 35 C DB 24 C WB Heating return air temperature 20 C DB 15 C WB outdoor temperature 7 C DB 6 C WB 4 direction discharge Power level dB Measuring place Anechoic chamber Location of microphone Octave b...

Page 22: ...to IEC 4 Reference acoustic intensity 0dB 10E 6 W m2 5 Curve for FXF32P7VEB in cooling mode Sound operation level dB Octave band center frequency Hz FXFQ32P 4TW28867 1 NOTES 1 Data is valid at free f...

Page 23: ...C 4 Reference acoustic intensity 0dB 10E 6 W m2 5 Curve for FXFQ80P7VEB in cooling mode Sound operation level dB Octave band center frequency Hz FXFQ80P 4TW28907 1 NOTES 1 Data is valid at free field...

Page 24: ...ure distribution All round air discharge air flow direction horizontal 2 0m s 1 5m s 1 0m s 0 5m s 22 C 24 C 26 C 20 C 4m 3m 2m 1m 0m 1m 2m 3m 4m FXFQ25P 4D057223 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m...

Page 25: ...ure distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 0m s 1 5m s 1 0m s 0 5m s 26 C 24 C 20 C 22 C FXFQ40P 4D057227 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m...

Page 26: ...ure distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 0m s 1 5m s 1 0m s 0 5m s 26 C 24 C 22 C 20 C FXFQ63P 4D057231 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m...

Page 27: ...und air discharge air flow direction horizontal 3 2m 3m 2m 1m 0m 3 2m 2 0m s 1 5m s 1 0m s 0 5m s 20 C 22 C 24 C 26 C 4m 3m 2m 1m 0m 1m 2m 3m 4m FXFQ100P 4D057235 4m 3m 2m 1m 0m 1m 2m 3m 4m 3m 2m 1m 0...

Page 28: ...3m 2m 1m 0m 1m 2m 3m 4m 3m 2m 1m 0m Cooling air velocity distribution All round air discharge air flow direction horizontal Cooling air temperature distribution All round air discharge air flow direct...

Page 29: ...r flow direction horizontal Heating air temperature distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m FXFQ25P 4D057222 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m...

Page 30: ...und air discharge air flow direction horizontal 2 0m s 1 5m s 1 0m s 0 5m s 0 25m s 26 C 25 C 27 C 24 C 23 C 22 C 4m 3m 2m 1m 0m 1m 2m 3m 4m 28 C FXFQ40P 4D057226 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m...

Page 31: ...und air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 0m s 1 5m s 1 0m s 0 5m s 0 25m s 26 C 24 C 22 C 28 C 23 C 25 C 27 C FXFQ63P 4D057230 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m...

Page 32: ...flow direction horizontal 3 2m 3m 2m 1m 0m 3 2m 2 0m s 1 5m s 1 0m s 0 5m s 0 25m s 28 C 27 C 26 C 25 C 24 C 23 C 22 C 4m 3m 2m 1m 0m 1m 2m 3m 4m FXFQ100P 4D057234 4m 3m 2m 1m 0m 1m 2m 3m 4m 3m 2m 1m...

Page 33: ...m 1m 2m 3m 4m 3m 2m 1m 0m Heating air velocity distribution All round air discharge air flow direction horizontal Heating air velocity distribution All round air discharge air flow direction horizonta...

Page 34: ...ted therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage In the broadest sense arising from or related...

Reviews: