background image

1

English

Thank you for purchasing this Daikin air conditioner.
Carefully read this operation manual before using the 
air conditioner. It will tell you how to use the unit prop-
erly and help you if any trouble occurs. This manual 
explains about the indoor unit only. Use it along with 
the operation manual for the outdoor unit. After read-
ing the manual, file it away for future reference.

CONTENTS

1. SAFETY PRECAUTIONS ............................................ 1
2. HOW TO ADJUST THE HORIZONTAL FAN 

DIRECTION ANGLE .................................................... 3

3. HOW TO CLEAN THE AIR FILTER ............................ 4
4. HOW TO CLEAN THE AIR OUTLET AND 

EXTERIOR .................................................................. 4

5. HOW TO CLEAN THE FRONT PANEL....................... 4
6. MAINTENANCE (FOR SERVICE PERSONNEL)........ 5
7. SOUND PRESSURE LEVEL ....................................... 5

The original instructions are written in English. All 
other languages are translations of the original 
instructions.

Important information regarding the 
refrigerant used

This product contains fluorinated greenhouse 
gases covered by the Kyoto Protocol.

(1)

 GWP = global warming potential

Periodical inspections for refrigerant leaks may be 
required depending on European or local legislation. 
Please contact your local dealer for more information.

1. SAFETY PRECAUTIONS

To gain full advantage of the air conditioner’s functions and to 
avoid malfunction due to mishandling, please read this oper-
ation manual carefully before use.
This product comes under the term “appliances not accessi-
ble to the general public”.

This appliance is intended to be used 
by expert or trained users in shops, in 
light industry and on farms, or for com-
mercial use by lay persons.

This appliance can be used by children 
aged from 8 years and above and per-
sons with reduced physical, sensory or 
mental capabilities or lack of experi-
ence and knowledge if they have been 
given supervision or instruction con-
cerning use of the appliance in a safe 
way and understand the hazards 
involved. Children shall not play with 
the appliance. Cleaning and user main-
tenance shall only be done by persons 
described in manual.

Drain pipe

Name plate

Air inlet 
(front and top of main unit)

Air filter 
(Inside intake vent)

Refrigerant pipe transmission 
wiring

Remote controller

Horizontal flaps 
(vertical air outlet direction adjustment flaps)

Louver 
(horizontal air outlet direction 
adjustment  flaps)

Air outlet

Ground wire

Conducts electricity from the 
unit into the ground to prevent 
electric shock.

(Indoor unit model name)

Packaging materials

If any packaging materials are 
included, please remove 
before operating.

Power supply wiring

Refrigerant type

R410A

GWP

(1)

 value

1975

01_EN_3P366851-15B.fm  Page 1  Tuesday, March 3, 2015  10:33 AM

Summary of Contents for FXAQ15PAV1

Page 1: ... Français Español Italiano Nederlands Português Ðóññêèé ÅëëçíéêÜ SYSTEM Inverter Air Conditioners OPERATION MANUAL MODELS Wall mounted type FXAQ15PAV1 FXAQ20PAV1 FXAQ25PAV1 FXAQ32PAV1 FXAQ40PAV1 FXAQ50PAV1 FXAQ63PAV1 ...

Page 2: ...f the air conditioner s functions and to avoid malfunction due to mishandling please read this oper ation manual carefully before use This product comes under the term appliances not accessi ble to the general public This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for com mercial use by lay persons This appliance can be used by children a...

Page 3: ...oms or in places with flammable gas corrosive gas or metal dust Using the air conditioner in such places may cause a fire or air conditioner failures Beware of a fire in case of refrigerant leakage If the air conditioner is not operating correctly i e not generating cool or warm air refrigerant leakage could be the cause Consult your local dealer for assistance The refrigerant used for the air con...

Page 4: ... compo nents Watch your steps at the time of air filter cleaning or inspection High place work is required to which utmost attention must be paid If the scaffold is unstable you may fall or topple down thus causing injury Do not remove the outdoor unit s outlet side grille The grille protects against the unit s high speed fan which may cause injury To avoid injury do not touch the air inlet or alu...

Page 5: ...filter with hot water of more than 50 C as doing so may result in discolora tion and or deformation Do not expose it to fire as doing so may result in burning 4 Attach the air filter Once cleaning is done be sure to replace the air filter as it was 5 Shut the front panel Refer to item No 1 6 Press the FILTER SIGN RESET button on the remote controller The TIME TO CLEAN AIR FILTER display vanishes 4...

Page 6: ... per form maintenance without daily mainte nance Before touching any of connection wirings be sure to turn off all power supply switches Contact professional personnel about attachment of accessories and be sure to use only accessories specified by the man ufacturer If a defect results from your own workmanship it may result in water leaks electric shock or fire Do not use flammable materials e g ...

Page 7: ...3P366851 15B EM11A083B 1504 HT ...