![Daikin FVXS60HVMA Service Manual Download Page 9](http://html1.mh-extra.com/html/daikin/fvxs60hvma/fvxs60hvma_service-manual_2459616009.webp)
Si06-962
Removal of Electrical Box
Removal Procedure
7
3. Removal of Electrical Box
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Disconnect the
connector [S49] and
release the harness
from the 6 hooks.
2
Pull the drip proof
cover and remove it.
(R14978)
[S49]
Hook
(R9706)
Drip proof cover