Si06-760
Removal of Control PCB
Removal Procedure
5
3. Removal of Control PCB
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the control PCB.
Remove the suction grille.
1
Remove the 2 screws
(top and bottom on the
left) off the electrical
box cover.
2
Open the electrical box
cover, and undo the
right-hand hook.
3
The figure at right
shows the control PCB.
Disconnect the
harnesses from the
terminal strip board.
Terminal strip board for
power supply
1-black
2-white
3-red
-green/yellow
Screws
(R4626)
Hook
(R4627)
(R18526)
Earth wire
Connecting Wire
Glass Tube
Thermal Fuse
JA
Wireless Remote
Controller Address
Jumper