background image

2

READ BEFORE OPERATION

Safety precautions

• Keep this manual where the operator can easily find them.
• Read this manual attentively before starting up the unit.
• For safety reason the operator must read the following cautions carefully.
• This manual classifies precautions into WARNINGS and CAUTIONS. Be sure to follow all precautions below: they are 

all important for ensuring safety.

WARNING

• In order to avoid fire, explosion or injury, do not operate the unit when harmful, among which flammable or 

corrosive gases, are detected near the unit.

• It is not good for health to expose your body to the air flow for a long time.
• Do not put a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will 

cause injury.

• Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric 

shocks, fire etc. 
For repairs and reinstallation, consult your Daikin dealer for advice and information.

• The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for 

some reason any refrigerant happens to leak into the room, make sure it does not come in 
contact with any flame as of gas heaters, kerosene heaters or gas range.

• If the air conditioner is not cooling (heating) properly, the refrigerant may be leaking, so call your dealer.

When carrying out repairs accompanying adding refrigerant, check the content of the repairs with our service staff.

• Do not attempt to install the air conditioner by your self. Incorrect work will result in water leakage, electric shocks or 

fire. For installation, consult the dealer or a qualified technician.

• In order to avoid electric shock, fire or injury, if you detect any abnormally such as smell of fire, stop the operation and 

turn off the breaker. And call your dealer for instructions.

CAUTION

• The air conditioner must be earthed. Incomplete earthing may result in electric shocks. Do not connect the 

earth line to a gas pipe, water pipe, lightning rod, or a telephone earth line.

• In order to avoid any quality deterioration, do not use the unit for cooling precision instruments, food, plants, 

animals or works of art.

• Never expose little children, plants or animals directly to the air flow.
• Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the 

indoor unit. It may cause incomplete combustion or deformation of the unit due to the heat.

• Do not block air inlets nor outlets. Impaired air flow may result in insufficient performance or trouble.

WARNING

If you do not follow these instructions exactly, the unit may 
cause property damage, personal injury or loss of life.

CAUTION

If you do not follow these instructions exactly, the unit may 
cause minor or moderate property damage or personal injury.

Never do.

Be sure to follow the instructions.

Be sure to earth the air conditioner.

Never cause the air conditioner (including the remote 

controller) to get wet.

Never touch the air conditioner (including the remote 

controller) with a wet hand.

01_EN_3P232468-8.fm  Page 2  Wednesday, June 4, 2008  10:33 AM

Summary of Contents for FTYN25GV1A

Page 1: ...FTYN25GV1A FTYN35GV1A MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual...

Page 2: ...autions 2 Names of parts 4 Preparation Before Operation 7 OPERATION AUTO DRY COOL HEAT FAN Operation 10 Adjusting the Air Flow Direction 12 POWERFUL Operation 14 TIMER Operation 15 CARE Care and Clean...

Page 3: ...t of the repairs with our service staff Do not attempt to install the air conditioner by your self Incorrect work will result in water leakage electric shocks or fire For installation consult the deal...

Page 4: ...cumulate around the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunc tions smoke or fire when making contact with electrical parts Do...

Page 5: ...4 Names of parts Indoor Unit 14 13 12 11 1 3 4 5 8 9 10 7 6 2...

Page 6: ...mode refers to the following table This switch is useful when the remote controller is missing 12 Operation lamp green 13 TIMER lamp yellow page 15 14 Signal receiver It receives signals from the rem...

Page 7: ...button Press this button once to start operation Press once again to stop it 6 MODE selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 7 FAN setting button It selects the ai...

Page 8: ...er When the system is not used for a long time take the batteries out We recommend replacing once a year although if the remote controller display begins to fade or if reception deteriorates please re...

Page 9: ...lder to a wall a pillar etc with the screws supplied with the holder 3 Place the remote controller in the remote controller holder ATTENTION About remote controller Never expose the remote controller...

Page 10: ...of electricity even while it is not operating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker OFF Use the air conditioner in the fol...

Page 11: ...ach pressing of the button advances the mode setting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION...

Page 12: ...tem switches into defrosting operation to take away the frost During defrosting operation hot air does not flow out of indoor unit Note on COOL operation This air conditioner cools the room by blowing...

Page 13: ...o increase your comfort To adjust the horizontal blades flaps 1 Press SWING button is displayed on the LCD and the flaps will begin to swing 2 When the flaps have reached the desired position press SW...

Page 14: ...e figure If the unit is operated after being stopped with the flaps pointed down in cooling or dry operation the flaps will automatically move to a horizontal position after about one hour to prevent...

Page 15: ...LCD To cancel POWERFUL operation 2 Press POWERFUL button again disappears from the LCD NOTE Notes on POWERFUL operation POWERFUL Operation can only be set when the unit is running Pressing the operati...

Page 16: ...ing down either button changes the setting rapidly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIM...

Page 17: ...r button changes the setting rapidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER...

Page 18: ...front panel into the slots and push them in all the way Close the front panel slowly and push the panel at the 3 points 1 on each sides and 1 in the middle CAUTION Units Don t touch the metal parts o...

Page 19: ...ed with lukewarm water then dry them up in the shade It is recommended to clean the air filters every two weeks Titanium Apatite Photocatalytic Air Purifying Filter The Titanium Apatite Photocatalytic...

Page 20: ...cause odour To order Titanium Apatite Photocatalytic Air Purifying Filter contact to the service shop there you bought the air conditioner Dispose of old filters as burnable waste Check that the base...

Page 21: ...nditioner is in defrost operation In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mist comes out of the indoor unit This happens when...

Page 22: ...ed Are the air flow rate and the air direction set appropriately Operation stops suddenly OPERATION lamp flashes Are the air filters clean Is there anything to block the air inlet or the outlet of the...

Page 23: ...y get foul after several seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenanc...

Page 24: ...23 MEMO...

Page 25: ...24 MEMO...

Page 26: ...0808 HT 3P232468 8 M08B042 Two dimensional bar code is a code for manufacturing...