20
Care
20
Prior to a long period of non-use
1.
Operate the FAN ONLY mode for several hours to dry out the
inside.
• Press
.
2.
After operation stops, turn off the circuit breaker for the room
unit.
3.
Take out the batteries from the remote controller.
We recommend periodical maintenance
• In certain operating conditions, the inside of the unit may get foul after several seasons of use, resulting in poor
performance. It is recommended to have periodical maintenance by a qualifi ed contractor in addition to regular cleaning by
the user.
• For qualifi ed contractor maintenance, please contact the dealer where you bought the unit.
Winter season
The icicles needs to be removed. Use gloves to avoid injury and unit damage.
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required depending on European or local legislation.
Please contact your local dealer for more information.
Important information regarding the refrigerant used
This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere.
Refrigerant type:
GWP
(1)
value:
675
R32
NOTICE
regarding tCO
2
eq
In Europe, the
greenhouse gas emissions
of the total refrigerant charge in the system (expressed as tonnes CO
2
-equivalent)
is used to determine the maintenance intervals. Follow the applicable legislation.
Formula to calculate the greenhouse gas emissions:
GWP value of the refrigerant × Total refrigerant charge [in kg] / 1000
Care and Cleaning