4.

Wiring.

, install as described in the installation manual supplied with the Multi outdoor unit.

1) Strip wire ends (15mm).
2) Match wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corre-

sponding terminals.

3) Connect the earth wires to the corresponding terminals.
4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer.
5) In case of connecting to an adapter system. Run the remote control cable and attach the S21. (Refer to 5. When connecting to 

an HA system.)

6) Shape the wires so that the service lid fits securely, then close service lid.

WARNING

1) Do not use tapped wires, stand wires, extensioncords, or starburst connections, as they may cause overheating, electrical 

shock, or fire.

2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the 

terminal block.) Doing so may cause electric shock or fire.

5.

When connecting to an HA system.

1) Remove the front grille. (3 screws)
2) Remove the electrical wiring box. (1 screw)
3) Remove the metal plate electrical wiring cover. (4 tabs)
4) Attach the connection cord to the S21 connector and pull the harness out through the notched part in the figure.
5) Replace the electrical wiring cover as it was,  and pull the harness around, as shown in the figure.

With a Multi indoor unit

Shape wires so that the service 
lid will fit securely.

Terminal block
Electrical component box

Wire retainer

Firmly secure wire retainer 
so that wires sustain no 
external stress.

Use the specified wire type.

1

2

3

1 2 3

L N

Safety

breaker

20A

Earth leakage

circuit breaker

Earth

When wire length exceeds

10m, use 2.0mm wires.

H05VV

Firmly fix the wires with

the terminal screws.

Outdoor unit

Indoor

unit

Power

supply

50Hz 220V - 240V

Firmly fix the wires with

the terminal screws.

Screw

HA cord

HA connector
(S21)

Tab

Tab

Push

Slide

Push

Metal plate 
electrical cover

Tab

Push

Main body

Notched part

4)

5) Replace the electrical 

wiring cover as it was,  
and pull the harness 
around, as shown 
in the figure.

Attach the connection cord to 
the S21 connector and pull the 
harness out through the 
notched part in the figure.

3) Remove the metal 

plate electrical 
wiring cover.

01_EN_3P170836-1.fm  Page 8  Thursday, October 20, 2005  3:18 PM

Summary of Contents for FTXS50EV1B

Page 1: ...tion manual R410A Split series Installationsanleitung Split Baureihe R410A Manuel d installation S rie split R410A Montagehandleiding R410A Split systeem Manual de instalaci n Serie Split R410A Manual...

Page 2: ...MC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF...

Page 3: ...due force on the electrical covers or panels Install covers over the wires Incomplete cover installation may cause terminal overheating electrical shock or fire If any refrigerant has leaked out durin...

Page 4: ...er 1 Turn on all the fluorescent lamps in the room if any and find the site where remote control signals are properly received by the indoor unit within 7 metres Installation Tips 1 Removing and insta...

Page 5: ...nd firmly engage the upper hooks 3 locations 2 Install 3screws of the front grill 3 Install the air filter and then mount the front panel 3 How to set the different addresses When two indoor units are...

Page 6: ...propriate length and wrap it with tape making sure that no gap is left in the insulation pipe s cut line Caulk pipe hole gap with putty Screws Field supply The mounting plate should be installed on a...

Page 7: ...ews Recommended mounting plate retention spots and Dimensions 125 60 83 503 5 44 5 290 52 1050 99 5 52 90 55 100 100 Through the wall hole 80mm Drain hose position 80 80 Recommended mounting plate ret...

Page 8: ...op of the indoor unit as a guide 4 Open the front panel then open the service lid Refer to Installation tips 5 Pass the interconnecting wires from the outdoor unit through the feed through wall hole a...

Page 9: ...ate hooks Secure indoor unit to the mounting plate with screws M4 12L 3 3 Wall Embedded Piping Follow the instructions given under 1 Insert the drain hose to this depth so it wont be pulled out of the...

Page 10: ...the electrical wiring box 1 screw 3 Remove the metal plate electrical wiring cover 4 tabs 4 Attach the connection cord to the S21 connector and pull the harness out through the notched part in the fi...

Page 11: ...from getting into the system as this would reduce the lifetime of the units 3 Never use piping which has been used for previous installations Only use parts which are delivered with the unit 4 Do nev...

Page 12: ...2 Be sure to insulate both the gas and liquid piping and to provide insulation dimen sions as below 3 Use separate thermal insulation pipes for gas and liquid refrigerant pipes Gas side Liquid side G...

Page 13: ...ner requires a small amount of power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the...

Page 14: ...0511 HT 3P170836 1 M05B096 00_CV_3P170836 1 fm Page 2 Thursday October 20 2005 9 43 AM...

Reviews: