background image

22

Note for Multi System

〈〈 

What is a “Multi System”? 

〉〉

This system has one outdoor unit connected to multiple indoor units.

Selecting the Operation Mode

1. With the Priority Room Setting 

present but inactive or not present.

When more than one indoor unit is operating, priority is 
given to the first unit that was turned on. 
In this case, set the units that are turned on later to the 
same operation mode (*1) as the first unit.
Otherwise, they will enter the Standby Mode, and the operation lamp will flash; this does not indicate malfunction.

(*1)

• COOL, DRY and FAN mode may be used at the same time.
• AUTO mode automatically selects COOL mode or HEAT mode based on the room temperature.

Therefore, AUTO mode is available when selecting the same operation mode as that of the room 
with the first unit to be turned on.

CAUTION

Normally, the operation mode in the room where the unit is first run is given priority, but the following situations are 
exceptions, so please keep this in mind.
If the operation mode of the first room is 

FAN Mode

, then using 

Heating Mode

 in any room after this will give priority to 

heating.

 In this situation, the air conditioner running in FAN Mode will go on standby, and the operation lamp will flash.

2. With the Priority Room Setting active.

See “Priority Room Setting” on the next page.

NIGHT QUIET Mode (Available only for cooling operation)

NIGHT QUIET Mode requires initial programming during installation. Please consult your retailer or dealer for assistance.
NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent 
annoyance to neighbors.

• The NIGHT QUIET Mode is activated when the temperature drops 5

°

C or more below the highest temperature 

recorded that day. Therefore, when the temperature difference is less than 5

°

C, this function will not be activated.

• NIGHT QUIET Mode reduces slightly the cooling efficiency of the unit.

OUTDOOR UNIT QUIET Operation 

(page 15.)

1. With the Priority Room Setting present but inactive or not present.

When using the OUTDOOR UNIT QUIET operation feature with the Multi system, set all indoor units to 
OUTDOOR UNIT QUIET operation using their remote controllers.
When clearing OUTDOOR UNIT QUIET operation, clear one of the operating indoor units using their remote controller.
However OUTDOOR UNIT QUIET operation display remains on the remote controller for other rooms.
We recommend you release all rooms using their remote controllers.

2. With the Priority Room Setting active.

See “Priority Room Setting” on the next page.

Cooling / Heating Mode Lock (Available only for heat pump models)

The Cooling / Heating Mode Lock requires initial programming during installation.Please consult your retailer or dealer 
for assistance. The Cooling / Heating Mode Lock sets the unit forcibly to either Cooling or Heating Mode. This function 
is convenient when you wish to set all indoor units connected to the Multi system to the same operation mode.

C

C

room

room

B

B

room

room

A

A

room

room

Living

Living

room

room

C

room

B

room

A

room

Living

room

Outdoor

unit

Summary of Contents for FTXS50CVMA

Page 1: ...FTXS50CVMA FTKS50BVMA MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual...

Page 2: ...n 7 OPERATION AUTO DRY COOL HEAT FAN Operation 10 Adjusting the Airflow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT QUIET Operation 15 HOME LEAVE Operation 16 INTELLIGENT EYE Operation 18 TIMER Op...

Page 3: ...aler When carrying out repairs accompanying adding refrigerant check the content of the repairs with our service staff Do not attempt to install the air conditioner by your self Incorrect work will re...

Page 4: ...cts in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such anima...

Page 5: ...4 Names of parts Indoor Unit Main unit control panel 7 14 11 12 13 4 3 15 1 2 9 10 8 6 5 The illustration shows a 50 class unit 17 16...

Page 6: ...once again to stop it The operation mode refer to the following table This switch is useful when the remote controller is missing 15 Packaging materials 50 class only If any packaging materials are i...

Page 7: ...E selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 QUIET button OUTDOOR UNIT QUIET operation page 15 9 FAN setting button It selects the airflow rate setting 10 SENSOR bu...

Page 8: ...When the system is not used for a long time take the batteries out We recommend replacing once a year although if the remote controller display begins to fade or if reception deteriorates please repla...

Page 9: ...der to a wall a pillar etc with the screws supplied with the holder 3 Place the remote controller in the remote controller holder ATTENTION About remote controller Never expose the remote controller t...

Page 10: ...you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions Operation outside this humidity...

Page 11: ...e button advances the mode setting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To c...

Page 12: ...peration frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does n...

Page 13: ...egin to swing 2 When the flap has reached the desired position press SWING button once more The flap will stop moving disappears from the LCD To adjust the vertical blades louvers 3 Press SWING button...

Page 14: ...the operation mode See the figure Three Dimensional 3 D Airflow Using three dimensional airflow circulates cold air which tends to collected at the bottom of the room and hot air which tends to collec...

Page 15: ...tes on POWERFUL operation POWERFUL Operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the LCD Priority is...

Page 16: ...ti system this function will work only when the OUTDOOR UNIT QUIET operation is set on all operated indoor units However if using priority room setting see Note for multi system page 22 This function...

Page 17: ...using HOME LEAVE operation for the first time please set the temperature and airflow rate for HOME LEAVE operation Record your preferred temperature and airflow rate 1 Press HOME LEAVE button Make sur...

Page 18: ...comfortably air conditioned room Push the HOME LEAVE Operation button again and the air conditioner will adjust capacity to the set temperature for normal operation Set the unit to HOME LEAVE Operatio...

Page 19: ...n 1 Press SENSOR button is displayed on the LCD To cancel the INTELLIGENT EYE operation 2 Press SENSOR button again disappears from the LCD EX TIMER ON CANCEL OFF QUIET 1 2 When somebody in the room N...

Page 20: ...passersby temperature range etc The sensor also mistakenly detects pets sunlight fluttering curtains and light reflected off of mirrors as passersby INTELLIGENT EYE operation will not go on during pow...

Page 21: ...ges the setting rapidly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER Operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the present time...

Page 22: ...ges the setting rapidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample set...

Page 23: ...ease consult your retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGHT QUIET Mode...

Page 24: ...g If the unit in Room A enters POWERFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slightly reduce...

Page 25: ...e front panel Align the rotation dowels on the left and right of the front panel with the slots then push them all the way in Close the front panel slowly Press the panel at both sides and the center...

Page 26: ...off easily wash them with neutral detergent thinned with lukewarm water then dry them up in the shade It is recommended to clean the air filters every two weeks Air purifying filter with photocatalyti...

Page 27: ...lts in poor heating or cooling 4 may cause odour To order air purifying filter with photocatalytic deodorizing function contact to the service shop there you bought the air conditioner Dispose of old...

Page 28: ...Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mist comes out of the indoor unit This happens when the air in the room is cooled into mist by the cold a...

Page 29: ...nd the outdoor units Clean the air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the lamp still...

Page 30: ...y get foul after several seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenanc...

Page 31: ...30 MEMO...

Page 32: ...31 MEMO...

Page 33: ...32 MEMO...

Page 34: ...0808 HT 3P232468 2 M08B036 Two dimensional barcodeisacode for manufacturing...

Reviews: