background image

22

English

CARE

Care and Cleaning

CAUTION  

 

To avoid possible bodily injury, units should be shutoff or disconnected before any cleaning or servicing is attempted.

Indoor unit, Outdoor unit and Remote controller

1. Wipe them with dry soft cloth.

Front panel

1. Open the front panel.

• Hold the panel by the tabs on the two sides and lift 

it unitl it stops with a click.

2. Remove the front panel.

• Supporting the front panel with one hand, release 

the lock by sliding down the knob  with the other 
hand.

• To remove the front panel, pull it toward yourself 

with both hands.

3. Clean the front panel.

• Wipe it with a soft cloth soaked in water.
• Only neutral detergent may be used.
• In case of washing  the panel with water, dry it with 

cloth, dry it up in the shade after washing.

4. Attach the front panel.

• Set the 3 keys of the front panel into the slots and 

push them in all the way.

• Close the front panel slowly and push the panel at 

the 3 points.
(1 on each side and 1 in the middle.)

• Check to see if the rotating axis in the upper center 

section is moving.

CAUTION

Units

• Don’t touch the metal parts of the indoor unit. If you touch those parts, this may cause an injury.
• When removing or attaching the front panel, use a robust and stable stool and watch your steps 

carefully. 

• When removing or attaching the front panel, support the panel securely with hand to prevent it 

from falling.

• For cleaning, do not use hot water above 104 

°

F, benzine, gasoline, thinner, nor other volatile 

oils, polishing compound, scrubbing brushes, nor other hand stuff.

• After cleaning, make sure that the front panel is securely fixed.  

Before cleaning, be sure to stop the operation and 
turn the breaker OFF.

Fit the key

into the slot.

01_EN_3P141693-1K.fm  Page 22  Tuesday, September 19, 2006  3:46 PM

Summary of Contents for FTXS09DVJU

Page 1: ...DAIKIN ROOM AIR CONDITIONER Operation Manual FTXS09DVJU FTXS12DVJU MODELS...

Page 2: ...n Before Operation 7 OPERATION AUTO DRY COOL HEAT FAN Operation 10 Adjusting the Airflow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT QUIET Operation 15 HOME LEAVE Operation 16 INTELLIGENT EYE Oper...

Page 3: ...dealer or qualified service repairman Do not attempt to install the air conditioner by yourself Improper installation could result in water leakage electric shocks or fire For installation consult yo...

Page 4: ...aikin Dealer Safely dispose of the packing materials Packing materials such as nails and other metal or wooden parts may cause stabs or other injuries Tear apart and throw away plastic packaging bags...

Page 5: ...4 English Names of parts Indoor Unit ON OFF...

Page 6: ...s switch once to start operation Push once again to stop it The operation mode refers to the following table This switch is useful when the remote controller is missing 13 Operation lamp green 14 TIME...

Page 7: ...Press once again to stop it 7 MODE selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 QUIET button OUTDOOR UNIT QUIET operation page 15 9 FAN setting button It selects the...

Page 8: ...to prevent liquid leak of the battery We recommend replacing once a year although if the remote controller display begins to fade or if reception deteriorates please replace with new alkali batteries...

Page 9: ...to a wall a pillar etc with the screws supplied with the holder 3 Place the remote controller in the remote controller holder ATTENTION About remote controller Do not put the remote controller in the...

Page 10: ...othly Note 2 1 Use low outdoor ambient cooling operation for equipment cooling applications only This operation is not intended for human comfort cooling 2 Intermittent noises may be produced by the i...

Page 11: ...setting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To change the temperature sett...

Page 12: ...s warmer In heating operation frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting ope...

Page 13: ...ontal blades flaps 1 Press SWING button The display will light up and the flaps will begin to swing 2 When the flaps have reached the desired position press SWING button once more The display will go...

Page 14: ...lways use a remote controller to adjust the flaps angle If you attempt to move it forcibly with hand when it is swinging the mechanism may be broken Be careful when adjusting the louvers Inside the ai...

Page 15: ...n POWERFUL Operation cannot be used together with QUIET Operation Priority is given to the function of whichever button is pressed last POWERFUL Operation can only be set when the unit is running Pres...

Page 16: ...NOTE Note on OUTDOOR UNIT QUIET operation This function is available in COOL HEAT and AUTO modes This is not available in FAN and DRY modes POWERFUL operation and OUTDOOR UNIT QUIET operation cannot b...

Page 17: ...first time please set the temperature and airflow rate for HOME LEAVE operation Record your preferred temperature and airflow rate 1 Press HOME LEAVE button Make sure is displayed in the remote contro...

Page 18: ...Before using HOME LEAVE operation section above HOME LEAVE operation is only available in COOL and HEAT mode It cannot be used in AUTO DRY and FAN mode HOME LEAVE operation runs in accordance with the...

Page 19: ...ed on the LCD To cancel the INTELLIGENT EYE operation 2 Press SENSOR button again disappears from the LCD EX F TEMP ON OFF POWERFUL HOME LEAVE MODE FAN SWING QUIET SENSOR 1 2 O N F TIMER ON CANCEL OFF...

Page 20: ...mode only Application range is as follows Sensor may not detect moving objects further than 16Ft away Check the application range Sensor detection sensitivity changes according to indoor unit locatio...

Page 21: ...g rapidly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the present time is not display...

Page 22: ...ing down either button changes the setting rapidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER...

Page 23: ...hade after washing 4 Attach the front panel Set the 3 keys of the front panel into the slots and push them in all the way Close the front panel slowly and push the panel at the 3 points 1 on each side...

Page 24: ...rgent thinned with lukewarm water then dry them up in the shade It is recommended to clean the air filters every two weeks Air purifying filter with photocatalytic deodorizing function gray The Air pu...

Page 25: ...s the air inlets and the outlets of the indoor unit and the outdoor unit Check that the water drains smoothly out of the drain hose during COOL or DRY operation If no drain water is seen water may be...

Page 26: ...en the air conditioner is in defrost operation In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mist comes out of the indoor unit This...

Page 27: ...appropriately Is the unit set to the INTELLIGENT EYE mode page 18 Operation stops suddenly OPERATION lamp flashes Are the air filters clean Is there anything blocking the air inlet or the outlet of t...

Page 28: ...eventual other parts should be done in accordance with the relevant local and national regulations Contact your authorized dealer for assitance In certain operating conditions the inside of the air co...

Page 29: ...R TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OPERATION HALT DUE TO DETECTION OF INPUT OVER CURRENT F3 HIGH...

Page 30: ...0611 HT 3P141693 1K M04B016G Two dimensional bar code is a code for manufacturing...