6
|
Unit installation
Installer reference guide
20
FTXP-N
Daikin room air conditioner
4P518023-14L – 2022.06
6 Unit installation
WARNING
Installation shall be done by an installer, the choice of materials and installation shall
comply with the applicable legislation. In Europe, EN378 is the applicable standard.
In this chapter
6.1
Preparing the installation site ................................................................................................................................................
20
6.1.1
Installation site requirements of the indoor unit ..................................................................................................
20
6.2
Opening the unit.....................................................................................................................................................................
21
6.2.1
To remove the front panel.....................................................................................................................................
21
6.2.2
To open the service cover......................................................................................................................................
22
6.2.3
To remove the front grille......................................................................................................................................
22
6.2.4
To remove the electrical wiring box cover ............................................................................................................
23
6.3
Mounting the indoor unit.......................................................................................................................................................
23
6.3.1
To install the mounting plate.................................................................................................................................
23
6.3.2
To drill a wall hole ..................................................................................................................................................
24
6.3.3
To remove the pipe port cover ..............................................................................................................................
25
6.4
Connecting the drain piping ...................................................................................................................................................
25
6.4.1
General guidelines..................................................................................................................................................
25
6.4.2
To connect the piping on right side, right-back, or right-bottom.........................................................................
26
6.4.3
To connect the piping on left side, left-back, or left-bottom................................................................................
27
6.4.4
To check for water leaks ........................................................................................................................................
28
6.1 Preparing the installation site
Choose an installation location with sufficient space to transport the unit in and
out of the site.
Do NOT install the unit in places often used as work place. In case of construction
works (e.g. grinding works) where a lot of dust is created, the unit MUST be
covered.
6.1.1 Installation site requirements of the indoor unit
INFORMATION
Also read the precautions and requirements in the
"2 General safety
precautions"
[
4
7].
INFORMATION
The sound pressure level is less than 70 dBA.
▪
Air flow.
Make sure nothing blocks the air flow.
▪
Drainage.
Make sure condensation water can be evacuated properly.
▪
Wall insulation
. When conditions in the wall exceed 30°C and a relative humidity
of 80%, or when fresh air is inducted into the wall, then additional insulation is
required (minimum 10 mm thickness, polyethylene foam).
▪
Wall strength.
Check whether the wall or the floor is strong enough to support
the weight of the unit. If there is a risk, reinforce the wall or the floor before
installing the unit.